Setting
24
8.3 Setting MS12, MR 30, AG 160
Risk of electric shock
– Work only at de-energized workplaces.
– Protect the workplace against unintentional switching-
on of the power supply.
– Only connect the motor to a network equipped with
operating circuit breakers.
– In case of AC power supply, make sure that the motor
capacitor is energized also in the switched off state.
– Discharge the capacitor only through a suitable
resistor.
The limit switches of the COMPACTA type MS12, MR30 and
AG160 slip-on geared motors are factory-set to the maximum
number of drive shaft revolutions specified by the customer. A
reserve for "turning free" in case of faulty electrical connection
(direction of rotation) is available.
BEWARE!
Risk of destroying the limit switch mechanics and the motor.
– The operation and safety limit switches, as well as the
thermal motor protection, must be connected to the
control circuit when carrying out whatever setting
work.
The faceplate of the setting and work screw shows setup help
information.
MS 12:
A