Fral FSW63 Series Скачать руководство пользователя страница 7

 

FSW63-14 Multilanguage 01/03/2016

 

32 

    FSW 63

 

 

 

 

 

 

 

 

 

PERSONAL PROTECTIVE EQUIPMENT 

 

When operating and maintaining the FSW unit, use the following personal protective equipment. 
 

 

Equiment: people who make maintenance or work with the unit, must wear an 
equipment in accordance with the safety Directives. They must wear accident 
prevention shoes with anti-slip sole where the paving is slippery. 

 

Gloves: During the cleanings and the maintenance operations, it’s necessary the use of 
appropriate  gloves.  In  case  of  gas  recharge,  It’s  complulsory  the  use  of  appropriate 
gloves to avoid the rick of freezing. 

 

 

Mask and goggles: Respiratory protection (mask) and eye protection 
(goggles) should be used during cleaning and maintenance operations. 

 

SAFETY SIGNS 
The equipment features the following safety signs, which must be complied with: 
 

 

General hazard 

 

Electric shock hazard

 

 

 

 

 It must not be used under explosive atmosphere. 

Machine  is  not  designed  to  be  used  by  people  (also  children)  whose  physical, 
sensory  or  mental  capabilities  are  reduced.  Also  people  without  experience  or 
knowledge of the machine can’t use it. 
People,  described  above,  can  use  this  machine  only  if  there’s  someone, 
responsable  of  their  safety,  which  watches  them  and  gives  them  instruction 
regarding the use of the machine. 
Children must be watched in order to be sure they don't play with machine. 

This machine is designed in order to be used by experienced users or trained in 
shops, light industry and farms. 
People without experiences can use this machine only for a commercial use.   

This  machine  must  be  always  connected  using  earthed  electrical  plugs  as 
required  for  all  electrical  appliances;  FRAL  Company  declines  any 
responsibility  for  any  danger  or  damage  whenever  this  norm  is  not 
complied with. 

 

Содержание FSW63 Series

Страница 1: ...FSW 63 DEUMIDIFICATORE DA PISCINA SWIMMING POOL DEHUMIDIFIER FSW63 MANUALE TECNICO TECHNICAL MANUAL M FSW63 14 Multilanguage 01 03 2016...

Страница 2: ...CK 33 FINS 33 TUBES 33 COMPRESSOR 33 FANS 33 ELECTRIC BOX 34 MICROPROCESSORS 34 Accessories 34 Body machine completely in Inox 34 Electric heaters in inox 2 0 kW 230 1 50 E H 34 Hot water coil H W C n...

Страница 3: ...TO THE HIDRAULIC CIRCUIT only for post heating version 42 MAINTENANCE AND PERIODIC CHECKS 42 IMPORTANT WARNINGS 42 AIR FILTER 43 ELECTRICAL CONNECTIONS 44 Generality 44 Main supply connection 44 Remot...

Страница 4: ...ctured and distributed according to safety and electro magnetic compatibility of the European Norms and Regulations MACHINES NORMS 2006 42 CE 17 05 2006 SECURITY REGULATIONS FOR LOW TENSION APPLIANCES...

Страница 5: ...e machines described in this manual have been designed according to the pertinent CE Norms in conformity with the MACHINES DIRECTIVES cited in the previous paragraph The machines are also complying wi...

Страница 6: ...removing first the socket from the plug This machine has been designed and manufactured in compliance with the strictest safety rules Therefore pointed instruments screw drivers wool needles or simila...

Страница 7: ...safety signs which must be complied with General hazard Electric shock hazard It must not be used under explosive atmosphere Machine is not designed to be used by people also children whose physical s...

Страница 8: ...spacing The best heat transmission is guaranteed by the fin collars that completely cover the tubes FINS They are manufactured by high precision pressing of aluminium aluminium epoxy painted copper o...

Страница 9: ...t water coil H W C nominal capacity 2 4 kW This battery can help you in heat the environment of the swimming pool thanks its efficient water hot coil due to the narrow step fins It is possible to assu...

Страница 10: ...pacity optional kW 2 2 Nominal Air flow m3 h 600 600 600 600 Available static pressure Pa 40 40 40 40 Refrigerant charge Tipo R410A R410A R410A R410A Defrost type Type Air Air Air HGD Sound pressure l...

Страница 11: ...0 8 0 PERFORMANCE TABLES FSW63 CONDENSED WATER AT DIFFERENT ROOM TEMPERATURE AND HUMIDITY CONDITIONS Roomcondition Condensed water Roomcondition Condensed water 10 C 60 10 l 24h 25 C 60 25 l 24 h 10 C...

Страница 12: ...FSW units application Operating Table standard units It is strongly recommended to let the units operate within the below reported limits Exceeding these limits it is not granted neither normal opera...

Страница 13: ...trol panel To access it disconnect the power supply and after removing the cover unscrew the protective cap with the help of a screwdriver INSPECTION TRANSPORT AND SITE HANDLING INSPECTION After recei...

Страница 14: ...wing points when determining the most suitable site for the unit installation location arrangement in order to guarantee adequate air flow no narrow spaces electrical power sup ply location accessibil...

Страница 15: ...rt of the machine CLEARANCES Absolute care must be taken to ensure adequate air volume to the air intake and fan discharge and to avoid air recirculation through the unit that will deeply reduce its p...

Страница 16: ...ipe It should be always avoided to form a doubble siphon which could obstruct the water flowing with the consequent risk of flooding the area Removing the case in order to insert the pipe and electric...

Страница 17: ...areful when operating in their surroundings even if the electric supply is disconnected WARNING The unit should be installed so that maintenance and or repair services be possible The warranty does no...

Страница 18: ...unit be sure that the electric supply has been disconnected In the inner side of the unit movable parts are present Be very careful when operating in their surroundings Aluminium coil fins are very s...

Страница 19: ...specting the national rules regarding plants This machines series belongs to the electric appliances functioning at low tension 230 V Before every operation on the electric section be sure that the el...

Страница 20: ...ties are reduced Also people without experience or knowledge of the machine can t use it People described above can use this machine only if there s someone responsable of their safety which watches t...

Страница 21: ...the environment makes the machine works in order to achieve the degree of humidity wanted When the temperature reached by the finned coil is too low the electronic control unit starts a defrost cycle...

Страница 22: ...anges and led REMOTE turn on Pay attention that if the humidity is set in cont position machine works not considering the remote control Remote LED lights up when the machine is controlled remotely ON...

Страница 23: ...e from 15 C to 32 C After 4 seconds the display stops flashing and the new set temperature is detected by the control unit HOUR COUNTER per visualizzare le ore di funzionamento sufficiente premere il...

Страница 24: ...ew points may cause great capacity loss with consequently longer operating periods it is advisable to set humidity values below 60 only if strictly necessary For the machine which has a second condens...

Страница 25: ...alarm resets automatically after 210 seconds If the alarm does not reset simultaneously press and SET HOURS for 10 seconds If the problem occurs again call for service HI t Combination of temperature...

Страница 26: ...andard version COM 4 F PUMP FAN T1 T2 T3 FLOAT HPS LPS R G A E V PUMP 0209 COMPRESSOR CAPACITOR L N T 234 RC AG 1 JUMP 2 JUMP 1 REMOTE CONTROL OPTIONAL P 3 GENERAC ALARM OPTIONAL REMOVE THE RESPECTIVE...

Страница 27: ...T1 T2 T3 FLOAT HPS LPS R G A E V PUMP 0209 COMPRESSOR CAPACITOR L N T 234 RC AG 1 JUMP 2 JUMP 1 REMOTE CONTROL OPTIONAL PUMP OPTIONAL 3 WAY VALVE B A THERMOSTAT OPTIONAL P COM 4 3 GENERAC ALARM OPTION...

Страница 28: ...S R G A E V PUMP 0209 COMPRESSOR CAPACITOR L N T 234 RC AG 1 JUMP 2 JUMP 1 GENERAC ALARM OPTIONAL REMOTE CONTROL OPTIONAL REMOVE THE RESPECTIVE BRIDGE IF YOU USE GENERAL ALARM BRIDGE 1 3 REMOTE CONTRO...

Страница 29: ...FLOAT HPS LPS R G A E V PUMP 0209 COMPRESSOR CAPACITOR L N T 234 RC AG 1 JUMP 2 JUMP 1 GENERAC ALARM OPTIONAL REMOTE CONTROL OPTIONAL REMOVE THE RESPECTIVE BRIDGE IF YOU USE GENERAL ALARM BRIDGE 1 3...

Страница 30: ...FSW 63 FSW63 14 Multilanguage 01 03 2016 55 DIMENSIONALI DIMENSIONAL DRAWINGS...

Страница 31: ...FSW63 14 Multilanguage 01 03 2016 56 FSW 63 DUCTED MACHINE It s possible to require a ducted verison of the machine Made By FRAL S r l Carmignano di Br PD Italy www fral it info fral it...

Отзывы: