FSW63-14 Multilanguage 01/03/2016
46
FSW 63
ELECTRONIC
CONTROL AND FUNCTIONING
The electronic board installed on the model FSW63 is connected directly to the power outlet of the
machine. It is equipped with three temperature probes and a humidistat.
The electronic control unit, by means humidistat that measures the relative humidity in the
environment, makes the machine works in order to achieve the degree of humidity wanted.
When the temperature reached by the finned coil is too low the electronic control unit starts a defrost
cycle to melt the ice formed in the finned coil.
This unit is programmed to stop the dehumidifier if the temperature drops below 4.5 ° C,(except for
HDG model that can work untill 0.5°C).
SIGNALLING PANEL
Units are provided with signalling light panel that indicates unit operational status. Below is reported a
brief description of their meaning.