![Fral FSW100 Series Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/fral/fsw100-series/fsw100-series_technical-manual_2326362042.webp)
FSW100-03 Multilanguage 04/11/2014
42
FSW 100
Ground connection is compulsory. Installer must connect ground cable with a dedicated
terminal on the apposite terminal block.
Main supply connection
The Electric Power Supply Connection must be carried out according to the indications given in
the Electric Diagram, by connecting the cable supplied with the machine and according with
safety norm.
Models FSW100 must be electrically powered with 1 phase-neutral-earth.
Remote humidistat connections
Remote humidistat connection must be realised according with electric diagram.
Connections must be done according to the electric wiring diagram specifications.
START UP
The line voltage fluctuations must not be more than ±5% of the nominal value, while
the voltage unbalance between one phase and another must not exceed 2%. If those
tolerances should not be respected, please contact our Firm to provide proper devices.
Electric supply must be in the limits shown: in the opposite case warranty will
terminate immediately.
Electrical connections therefore must be always done according to the instructions
reported on the wiring diagram enclosed with the unit and norms and laws.
It’s very important to keep ground wire longer than the others: in this way if the cable
is pulled, the ground wire is the last to be removed.
Since there’s no fixing device for the main supply, the power cable must be fixed with
cable ducts or similar. The cable duct must enter inside the machine through the
apposite holes.
Machine is not designed to be used by people (also children) whose physical,
sensory or mental capabilities are reduced. Also people without experience or
knowledge of the machine can’t use it.
People, described above, can use this machine only if there’s someone, responsable
of their safety, which watches them and gives them instruction regarding the use of
the machine.
Children must be watched in order to be sure they don't play with machine.