background image

13

English

The output MUX also have a led indicator showing the status: 

•  GREEN: MUX in normal working condition.

•  DARK GREEN: the MUX is activated but overflow monitoring is enabled.

•  GREY: the MUX is off

•  RED: the MUX has recorded a bitrate overflow.

6.3 STATUS MENU

In the 3DGFLEX ‘HOME’ menu, select one of the modules to access its programming. 

You can go back to the Home page at any time by clicking on the key on the toolbar at the top of the screen.

The module programming opens with the status window (Fig. 3).

The STATUS menu allows checking the product software release and relative serial number.

The INPUT section gives the status of all inputs, showing the main data of the level parameters and reception 

quality (CBER and MER), plus the name and number of the received channel.

Each input also has a led indication that shows the input status, with the following signals:

•  GREEN: the input is enabled and the receiver is locked (USB: enabled and file read correctly).

•  YELLOW: the input is enabled but the receiver is not locked (USB: file missing, unselected or incompatible).

•  RED: input current overload (remote power).

•  GREY: the input is not enabled

The OUTPUT section gives the status of the 4 output MUX, displaying the channel and the output frequency, 

the RF level, the total bitrate used by the inserted programs and the bitrate available for the MUX. This data Is 

given in both numerical and graphic form using the horizontal format bar: the GREEN part of the bar shows the 

instantaneously used bitrate, the GREY part shows the maximum peak and the WHITE part shows the bitrate 

that is still available.

There is also the RESET PEAK button to reset the peak level and the overflow details.

Each output MUX also has a led indication that shows the MUX status, with the following colours:

•  GREEN: the MUX is in normal working conditions.

•  DARK GREEN: the MUX is activated but overflow monitoring is deactivated.

•  GREY: the MUX is off.

•  RED: the MUX has recorded a bitrate overflow.

NOTE: the input and output sections can be scrolled by using the prev. and next keys, or by dragging to the right 

and left screen with the mouse pointer. The bitrate overflow alarm is shown by the red dot.

Fig 3

Содержание 3DG-4ASI-4T

Страница 1: ...3DG 4ASI 4T OPERATING INSTRUCTIONS...

Страница 2: ...ENT WITH POWER PLUG the plug must be installed close to the equipment and easily accessible The unit must be connected to the ground electrode of the antenna system in compliance with the EN 60728 11...

Страница 3: ...it POOL technology see chapter 2 3 which allows decrypting programs from the same transport stream There Is also a USB port to rapidly update the firmware download and update configuration parameters...

Страница 4: ...Recovery phase 2 3 POOL Technology The 3DG 4ASI 4T module is part of the evolved 3DGFLEX family The main innovation is the use of POOL technology POOL technology enables total communications between a...

Страница 5: ...the central unit which must be turned off 2 Turn on the central unit and wait for initialisation the Fracarro logo appears on the display 3 Connect the antennal cables to the respective inputs 4 To a...

Страница 6: ...rms an entered value or enters the menu submenu or Erases an entered value or leave the menu Are used to navigate the various menu items Modify the parameters Enter values Saves the changes S 9 WXYZ 0...

Страница 7: ...the DVB T DVB C output signal from the 3DG 4ASI 4T module OUTPUT FLOWCHART DVB T DVB C DVB C DVB T the output signal standard can be selected from DVB T and DVB C and depending on the standard that is...

Страница 8: ...VEL regulate the output level in dBuV at steps of 1 dBuV this parameter automatically changes the level value of the adjacent MUX in the same pair SPECTRUM set the spectrum NORMAL or INVERTED accordin...

Страница 9: ...PEAK USED measures the maximum peak bitrate bit s used by the programs in the output MUX BR PEAK AVAILABLE measures the total peak bitrate bit s available in the output MUX RESET BR PEAK to reset the...

Страница 10: ...he program independently from the source input PRIORITY ordered by priority or according to the position number associated to the program PROGRAMS LIST set the list of output channels ADD add the sele...

Страница 11: ...browser It is very important not to configure the 6 modules by using 6 different browsing boards at the same time as the CU does not respond to multiple parameter requests from the web rather it take...

Страница 12: ...uding network parameters and the other modules from position 1 to 6 may or may not be displayed If the module is in this window we can view its status To be precise module 3DG 4ASI 4T gives The symbol...

Страница 13: ...abled but the receiver is not locked USB file missing unselected or incompatible RED input current overload remote power GREY the input is not enabled The OUTPUT section gives the status of the 4 outp...

Страница 14: ...r locking status the signal quality and the transport stream received CLICK ON SAVE TO STORE THE CHANGES 6 5 USB INPUT MENU The product allows distributing a user transport stream from a TS file the p...

Страница 15: ...and saves a file in the USB drive with the same name but an FR extension to make future use more fluid In the right section the lock led should turn on green to show that the file is being successfull...

Страница 16: ...of the other mux In the same pair are also Immediately changed The 2 pairs are divided MUX1 MUX2 and MUX3 MUX4 RF LEVEL to set the output power in dBuV in the range foreseen by the technical specific...

Страница 17: ...of the MUX and then release the button The OUTPUT columns in the table on the right show The program name the input and module it comes from the program priority the lower the number the higher the pr...

Страница 18: ...ons can be performed on each program PID Delete the PID the deleted PID line is highlighted grey reinstate the PID change the PID Note Click on Apply to save the changes The PID advanced configuration...

Страница 19: ...o tune the channels of the TV Auto program name if enabled this innovative function allows automatically assigning a new progressive name to the programs writing it in the spaces base name e g program...

Страница 20: ...ction FIG 12 you must enable monitoring and you can enable saving the log list on a local file the time for file saving and enable sending an email with the alarm events In the second section set the...

Страница 21: ...n Monitoring Status The time interval and number of monitoring attempts can be set for the various parameters and alarms Some of the monitored parameters are given in series the others can be identifi...

Страница 22: ...or output programs NOTE Click on Apply to save the changes In the green option bar at the top select Configuration Monitoring Log to open the following screen In this screen you can display and search...

Страница 23: ...on the PC or USB drive In an XML format file 8 3 UPLOAD CONFIGURATION From the OPERATIONS LOAD CONFIGURATION FROM FILE USB DRIVE menu you can access the configuration save pages respectively from a PC...

Страница 24: ...the 3DG 4ASI 4T the following general instructions should be observed Decide whether you want to use the ALL PID OUT function or to program every single program PID that will have to be available in...

Страница 25: ...e programs are broadcast without the loss of any data To facilitate this the system offers a band graphic indicator in the web management which is updated automatically every second The length of the...

Страница 26: ...be updated in the field by uploading the firmware saved on a USB drive directly on the module through its USB port see the programming flowchart IMPORTANT do not remove the USB drive while the update...

Страница 27: ...ach pair of channels dB 20 0 Output impedance Ohm 75 Spurius dBc 50 MER dB 37 USB File System FAT 32 File extension TS Average file bitrate Mbps 15 CAM mode Number of CAMS 2 can be configured in INPUT...

Страница 28: ...n purchasing a new appliance of the same type as part of the One for One scheme The correct collection and subsequent recycling treatment and environmentally friendly disposal of appliances contribute...