7

2. PRE-INSTALLATION

The following is required to ensure that the site is ready for 
installation and that all materials are included.

NOTICE

 Make sure that the site is ready and the 

PowerSewer® is undamaged and complete before disconnecting an 
existing sewage system or connection

2.1 PowerSewer® Inspection

The packing materials for your PowerSewer® grinder pump pressure 
sewer system are specially designed to prevent shipping damage.  
As a precaution, the system should remain in the packaging until 
you are ready to install it. When you are ready to install the system, 
remove the packaging materials. Examine the equipment for any 
hidden damage that may have occurred during shipping. If damage 
has occurred, handle all claims with the shipper.

NOTICE

 

If the collection tank or other PowerSewer® 

component is suspected of being damaged, installation should be 
suspended until the extent of the damage can be determined by 
an authorized Franklin Electric representative Any field repairs or 
alterations must be authorized in writing by Franklin Electric and then 
performed in accordance with Franklin Electric written instructions

2.2 Verify Site Readiness

The PowerSewer® grinder pump pressure sewer system is shipped 
ready for immediate installation and operation. To facilitate and speed 
installation, make sure that the site is prepared. Site preparation 
requirements include:

•  Location of collection tank, piping, and accessory  

installations identified

•  Suitable excavation equipment
•  Rounded aggregate for collection tank foundation
•  Concrete for collection tank ballast (minimum 7 cubic feet)
•  Approved backfill materials (see section 10.1, Approved  

Backfill Materials)

•  Determine main electrical supply power and make sure pump 

and panel are compatible 

•  20/30 Amp, circuit breaker for the main electrical supply power 

(refer to pump rating for electrical requirements)

•  Inlet piping and fittings, 4" Schedule 40 PVC
•  Discharge piping, 1-1/4" Schedule 40 or SDR 21 PVC or SDR 11 PE3408
•  Vent piping and fittings, 2" Schedule 40 PVC
•  12-gauge, 3-conductor with ground, direct bury cable  

supplied by installer

•  18-gauge, 6-conductor, direct bury cable 

supplied by installer

•  18-gauge 3-conductor direct bury cable for IGPDS-M 

supplied  

by installer

.

WARNING

 

Hazardous voltage can shock, burn or 

cause death Verify required electrical supply power for specific 
grinder pump Using the incorrect voltage or phase can cause fire or 
damage to the pump motor or cause sever personal injury and will 
immediately void the warranty

2.3 General Installation Steps

The following installation steps are an outline of the detailed 
installation requirements:

1.  Excavate for collection tank, inlet piping, electrical cables  

and discharge piping

2. Set and ballast collection tank
3. Install inlet, vent, and discharge piping
4. Run electrical cabling between property  

service panel, control panel

5. Bolt cover on
6. Backfill collection tank, piping, and electrical cables
7. Install pump
8. Make wiring connections
9. Turn system on and test

NOTICE

 

Failure to install this product according to the 

instructions and warnings found in this manual will void all warranties 
associated with this product and may result in serious injury or death

Содержание PowerSewer V4PS

Страница 1: ...V4PS Installation Operation Maintenance Manual...

Страница 2: ...and maintenance instructions may result in electrical shock or fire hazard personal injury or death unsatisfactory performance equipment failure and will void the warranty If you have any questions ca...

Страница 3: ...ng the Vent 11 7 1 Vent Coupling Location 7 2 Vent Cap Location 7 3 Vent Pipe Slope 7 4 Solvent Cementing Vent Piping and Fittings 7 5 Installing the Remote Vent Cap 8 Locating and Mounting the Contro...

Страница 4: ...for Field Installation Fiberglass Basin Cover Wet well access cover with polyethylene seal using 3 8 16 SST bolts to fasten cover to basin Spring Release Float Tree Assembly SST Isolated Pump Support...

Страница 5: ...or removal of the manhole bolts and cutting ring bolts 1 Phillips screwdriver to open the control panel cover Small flathead screwdriver used to connect wire to control panel Wire strippers Small chan...

Страница 6: ...tallation should be suspended until the extent of the damage can be determined by an authorized Franklin Electric representative Any field repairs or alterations must be authorized in writing by Frank...

Страница 7: ...aggregate for collection tank foundation Concrete for collection tank ballast minimum 7 cubic feet Approved backfill materials see section 10 1 Approved Backfill Materials Determine main electrical su...

Страница 8: ...im should be at least 1 1 2 above final grade The final grade should slope away from the collection tank to avoid surface water from ponding on or around the collection tank and cover NOTICEDo not ins...

Страница 9: ...ary 4 4 Applying Solvent Cement Solvent cement must be applied immediately to the primed surfaces before the primer dries in an alternating three coat application Using a brush or applicator sized no...

Страница 10: ...e Then dry fit service lateral from property into elbow or sanitary tee Make any necessary adjustments to the drop inlet pipe for a proper fit NOTICEIf a cleanout is not available in the property serv...

Страница 11: ...utlined in section 4 0 Solvent Cementing Joints NOTICEJoints and fittings in the vent piping must be watertight If not ground and surface water could infiltrate the PowerSewer system resulting in unne...

Страница 12: ...ause fire or damage to the pump control panel or cause severe personal injury and will immediately void the warranty Control Panel for Pump Power Wiring Preparation Strip back the outer jacket of the...

Страница 13: ...as defined by ASTM D 2321 include clean gravels and sands with less than 5 fines and clean compactible soil that contain less than 12 fines Class 2 materials consist of rounded materials and are less...

Страница 14: ...e junction box The length of the power cord is 10 long regardless of the size of the tank Do not leave extra cord inside of wet well The cable may become entangled in the rotating cutters or interfere...

Страница 15: ...tor features with the property owner 12 OPERATION The PowerSewer grinder pump sewer system is equipped with a float control system that continuously controls the grinder pump operation 12 1 Automatic...

Страница 16: ...List Equip yourself with the proper installation operation and maintenance tools before performing any work on or near the PowerSewer system Review section 1 2 Installation and Maintenance Tool List...

Страница 17: ...draulic Diaphragm Seal TPV Pump Stand Off PVC 1 1 4 Discharge Pipe SST 2 HP Centrifugal Grinder Pump IGP M IGP A IGPH M IGPH A IGPDS M IGPDS A Discharge Depth See Table A Basin Height See Table H 42 1...

Страница 18: ...ll Bearing Upper Single row ball 6203 Ball Bearing Lower Single row ball 6306 Seal Housing Cast iron with epoxy coating Mechanical Seal Carbon Ceramic Volute Cast iron with epoxy coating Impeller Bras...

Страница 19: ...and third party approval Motor Cover Cast iron with epoxy coating Motor Cover O ring Nitrile Motor Design Single phase capacitor start capacitor run or three phase depending on pump model Insulation C...

Страница 20: ...hes must be rated a minimum of 2 Amps at 120 V 208 230 VAC PUMP POWER CABLE 208 230 VAC 115 VAC 1 PHASE 60 HERTZ POWER SUPPLY CONTROL PANEL 515351 515357 COMMON RUN START PANEL GRD BLUE BLACK ORANGE B...

Страница 21: ...60 C copper wire minimum 6 Level switches must be rated a minimum of 2 Amps at 120 V THREEPHASE IGP IGPHMANUALGRINDER Wiring Diagram 208 240 480 600 VAC 3 PHASE 60 HERTZ POWER SUPPLY INCOMING POWER CO...

Страница 22: ...Ball Bearing Upper Single row ball 6203 Ball Bearing Lower Single row ball 6306 Seal Housing Cast iron with epoxy coating Mechanical Seal Carbon Ceramic Volute Cast iron with epoxy coating Impeller Br...

Страница 23: ...Motor Design Single phase capacitor start capacitor run Insulation Class F Overload Protection Internal on winding thermal protector Motor Shaft AISI 300 series stainless steel Ball Bearing Upper Sin...

Страница 24: ...M FLOAT BLACK BLACK BLACK WHITE WHITE WHITE GREEN WHITE BLACK TANK JUNCTION BOX MOUNTED IN TANK DRY WELL NOTE This is a control drawing only and does not re ect the actual locations of cable penetrati...

Страница 25: ...with fluoroelastomer FKM bellows and stationary ceramic with fluoroelastomer FKM O ring Lower Type 21 spring loaded rotating silicon carbide with fluoroelastomer FKM bellows and stationary silicon car...

Страница 26: ...RUN START SEAL FAIL PUMP OFF FLOAT PUMP ON FLOAT HIGH LEVEL ALARM FLOAT TANK JUNCTION BOX MOUNTED IN TANK DRY WELL SENSOR CABLE NOTE This is a control drawing only and does not re ect the actual locat...

Страница 27: ...TANK JUNCTION BOX MOUNTED IN TANK DRY WELL 12 AWG PUMP CABLE 125 FT MAX COMMON RUN START TB4 SEAL FAIL 18 AWG FLOAT CABLE 18 AWG SEAL FAIL CABLE NOTE This is a control drawing only and does not re ect...

Страница 28: ...t check valve not provided shown for reference only 10 Stop valve not provided shown for reference 11 Force main or gravity line 12 Pump power and or control float control direct bury cable or continu...

Страница 29: ...ty does not cover any labor or shipping charges The Company shall not be liable for any costs or charges attributable to any product testing maintenance installation repair or removal or for any tools...

Страница 30: ...RN AND OR INSTRUCT LOSS OF OTHER PRODUCTS OR COSTS OF ENVIRONMENTAL REMEDIATION OR DIMINUTION IN PROPERTY VALUE THE REMEDIES OF THE PURCHASER SET FORTH HEREIN ARE EXCLUSIVE AND THE LIABILITY OF THE CO...

Страница 31: ...31 NOTES...

Страница 32: ...Road Fort Wayne IN 46809 Tel 866 271 2859 Fax 886 281 2709 www franklinengineered com Form 998076 Rev 002 12 20 For technical assistance please contact 866 271 2859 www franklinengineered com FPSEngin...

Отзывы: