DC Grounding
The Chassis Ground point on the inverter/charger is used to connect the
chassis of the inverter/charger to your system’s DC grounding point, as
required by regulations for some installations. Use copper wire that is either
bare or provided with green insulation.
The grounding guideline given below assumes you are using the code-
compliant DC supply cable and fuse sizes indicated on
page 24. If you are using different sizes, refer to the applicable code for DC
grounding detail.
To connect the chassis ground:
1. Using the appropriate wrench, loosen the nut on the bolt of the chassis
ground point shown in Figure 18.
2. Connect the grounding cable between the chassis ground point and the
DC grounding point for your system.
In an RV or vehicle installation, the DC grounding point will usually be the
vehicle chassis or a dedicated chassis ground bus.
For marine installations, refer to the applicable local code for marine DC
grounding detail.
3. Tighten the nut to a torque of 1.0–1.25 ft-lbs (1.47–1.7 Nm).
Chassis Grounding Point
Figure 18
DC Wiring and DC Grounding