CFM Configuration
232
Chapter 31. CFM Configuration
31.1 Brief Introduction to CFM
CFM (Connectivity Fault Management, the connectivity fault management protocol),
defined by the IEEE 802.1ag standard is a Layer 2 link on the VLAN-based end to end OAM
mechanism used to Carrier Ethernet fault management.
31.1.1 CFM Concepts
Table 31-1 CFM concepts
Concept
Remark
MD
Maintenance field indicates that even the fault detection is covered through a network
of its boundary is configured on a port range defined by the MEPs. Maintenance of
the domain of "maintaining the domain name" to identify, according to network
planning can be divided into eight levels.
Between different domains can be maintained adjacent to or nested,
but can’t cross,
and the nested domain can only be maintained by the high-level domain to the low
level maintenance nested, that is, low-level maintenance of the domain must be
included in the domain of high-level maintenance department.
Maintenance
set
Within the maintenance domain can be configured as needed to maintain multiple
sets, each set is maintained within some maintenance to maintain the set point.
Maintenance set to "maintain the domain name + maintenance set name" to identify.
Maintain set service on a VLAN, to maintain focus on the maintenance point of
sending packets of the band are the VLAN tag, at the same time maintaining focus on
the maintenance point can receive by maintaining focus on its maintenance point sent
the message.
Maintenance
point
Maintenance points configured on a port, part of a maintenance set, can be divided
into MEPs and MIPs two.
(1) MEP ID in order to maintain endpoint identity, which defines the scope and
maintenance of the domain boundary. MEP has a directional, sub-UP MEP and
DOWN MEP for the two. MEP direction that the maintenance of domain relative to the
location of the port. DOWN MEP is the port where to send its message, UP MEP port
where it is not sent to the message, but it is the port to the device send its message.
(2) Maintenance in the maintenance of the domain between points within the
department, not the main action issued CFM protocol packets, but can handle and
respond to CFM protocol packets.
31.1.2 CFM Main Function
Connectivity fault detection based on a reasonable and effective application deployment
and configuration over the network, its function is maintained in the configuration between
points, as long as the following functions: