background image

4

IMPORTANT SAFETY INSTRUCTIONS

1. 

READ AND FOLLOW ALL INSTRUCTIONS

2. 

DANGER

 - 

Do not lay across the foot well. Always sit in an upright position.

3. 

WARNING

 - 

To reduce the risk of injury, do not permit children to use this product 

unless they are closely supervised.

4. 

CAUTION

 - 

Water temperature may rise when jets are operating on “high” speed for 

extended duration.
5. A bonding lug has been provided on the outside of the Equipment Package electrical control 
box. The lug permits the connection of No. 8 AAWG (8.42mm^2) solid copper bonding 
conductor between the Equipment Module and all other electrical equipment and exposed metal 
in the vicinity, as may be needed to comply with local regulations.

6. 

WARNING

 - 

This unit must be hardwired only to supply circuit that is protected by 

ground fault circuit interrupter (GFCI) see diagram.  Such a GFCI is required by most building 
codes and should be provided by the installer and must be tested before each use. Consult GFCI 
manufacturers’ instructions for correct testing and operation.
7. The electrical supply for this product must include a suitable rated switch or circuit
breaker to open all ungrounded supply conductors to comply with the National Electrical Codes. 
The disconnection means must be readily accessible to the tub occupant but installed at least 5 
feet (1.5M) from spa water.
8. Spas must be installed with drainage for electrical equipment compartment.
9. Be sure the water always flows freely from the hydrotherapy jets within the spa. Any blockage 
or restriction to this water flow by persons or objects may damage system components, create an 
electrical shock hazard, and or cause water damage to the surrounding area.
10. To avoid damage to the pump(s) and heater, the Equipment must never be operated unless the 
spa is filled with water.

WARNING

CHILDREN SHOULD NOT USE SPAS OR HOT TUBS WITHOUT 

ADULT SUPERVISION

AVERTISSEMENT:

 NE PAS LAISSER LES ENFANTS UTILISER UNE CUVE DE 

RELAXATION SANS SURVEILLANCE

WARNING

:

 DO NOT USE SPAS OR HOT TUBS UNLESS ALL SUCTION GUARDS 

ARE INSTALLED TO PREVENT BODY AND HAIR ENTRAPMENT

AVERTISSEMENT

: POUR ÈVITER QUE LES CHEVEUX ou UNE PARTIE DU CORPS 

PUISSENT ETRE ASPIRÈS, NE PAS UTILISER UNE CUVE DE RELAXATION SI LES 
GRILLES DE PRISE D’ASPIRATION NE SONT PAS TOUTES EN PLACE

Содержание XL SWIM SPA SERIES

Страница 1: ...Owner s Manual Copyright Four Winds Spas 2016 Specifications subject to change...

Страница 2: ...d helpful tips on enjoying your new Four Winds Spa Also you can enter your spa s information in the Record of Ownership section on page 23 for quick reference in the future Also enclosed in this manua...

Страница 3: ...Electrical Installation Instructions 12 13 Electrical Safety 14 Understanding Spa Controls and Features 15 Beginning Startup Procedures 15 16 Hot and Cold Weather Use 16 17 Troubleshooting 18 Recomme...

Страница 4: ...ectrical supply for this product must include a suitable rated switch or circuit breaker to open all ungrounded supply conductors to comply with the National Electrical Codes The disconnection means m...

Страница 5: ...purpose 14 DANGER RISK OF ELECTRICAL SHOCK Do not permit any electrical appliance such as a light telephone radio or television within 5 feet 1 5m of a spa 15 WARNING Water temperature in excess of 38...

Страница 6: ...od pressure and circulation 27 Because occasional users of the spa may not be aware of all the potential risk associated with spa usage they should be made aware of these Important Safety Instructions...

Страница 7: ...partment door open Self closing door provided B CAUTION Risk of Electric Shock Replace components only with identical components C WARNING Prevent Electrocution Do not connect any auxiliary components...

Страница 8: ...d as follows Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98 6 F 37 C The Symptoms of Hyperthermia Include Dizzine...

Страница 9: ...make sure that the surface can offset at least 100 lbs 45 kg per square foot You dealer is not usually qualified to make judgments on weight bearing abilities of structures so always consult a qualif...

Страница 10: ...seal around the conduit placed through the hole in the side panel All 120 Volt capable spas require a Dedicated 15 AMP GFCI service connection An optional 15 Amp GFCI 12ft cable is available from Four...

Страница 11: ...02895224 3 All field installed metal components such as rails ladders drains or other similar hardware within 5 feet of the spa or hot tub shall be bonded to the equipment grounding bus with copper c...

Страница 12: ...all of your connections are correct Generally if the breaker will not stay engaged it is a wiring problem with the neutral wire Note The neutral and the ground wires cannot touch anywhere in between t...

Страница 13: ...13 EURO Wiring Specs 50 Hz 1 x 32 AMP Service for 1 3 Pump Spas 2x 32 AMP Service for 4 Pump Spas...

Страница 14: ...he power of a pump between two sets of jets or a set of jets and a Master Massage jet or jets This is a very large valve Bullet Style Jet These jets offer a straight water stream and this type cannot...

Страница 15: ...e Two pump EU spas will heat about 4 6 degrees per hour All of these times are approximate If your spa has a PR or Priming Mode code on the topside it will take 4 to 6 minutes for it to go into the re...

Страница 16: ...cian check voltage at the spa control system It is easy to blow fuses when first wiring a new spa if you accidentally put the wires in the wrong place or touch anything powered in the spa control pack...

Страница 17: ...nd August being it is the hottest part of the day To set your spa filtration time to filter between certain hours first be sure you are on proper cycle generally F2 or FIL2 then shut off the breaker t...

Страница 18: ...the left and then pull it out about 3 This will lock the tube into place so you can remove the cap and not lose any water Then attach a water hose to the tube and push the tube in about half way and d...

Страница 19: ...reset shut off the power to the spa and call your dealer or service organization OH Overheat The spa has shut down One of the sensors has detected that the spa water is 110 F at the heater DO NOT ENTE...

Страница 20: ...rvice organization LF Persistent low flow problems Displays on the fifth occurrence of HL message within 24 hours Heater is shut down but other spa functions continue to run normally Follow action req...

Страница 21: ...s to measure it Calcium hardness is sometimes called total hardness and is simply a measure of the minerals in your water including calcium and magnesium If you do not have enough hardness your spa wi...

Страница 22: ...tion drain or filter lid or weir assembly This has been reported in persons who when submerging themselves underwater allowing hair to come close and or within the reach of the suction fittings suctio...

Страница 23: ...s XL Swim Spa Record of Ownership Four Winds XL Swim Spa Record of Ownership Four Winds Model Serial Number Date Purchased Dealer Name Dealer Number Dealer Address Dealer City State Service Technician...

Отзывы: