User Manual
Xiamen Four-Faith Communication Technology Co.,Ltd.
Page 36 of 42
Add
:
J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http
:
//www.fourfaith.com Tel
:
+86 592-6300326 6300325 6300324 Fax
:
+86 592-5912735
Stopbit: The serial port’s stopbit
Flow Control: The serial port’s flow control type.
Enable Serial TCP Function: Enable the serial to TCP function
Protocol Type: The protocol type to transmit data.
UDP(DTU) – Data transmit with UDP protocol , work as a Four-Faith DTU which has
application protocol and hear beat mechanism.
Pure UDP – Data transmit with standard UDP protocol.
TCP(DTU) -- Data transmit with TCP protocol client , work as a Four-Faith DTU which has
application protocol and hear beat mechanism.
Pure TCP -- Data transmit with standard TCP protocol Client.
TCP Server -- Data transmit with standard TCP protocol Server.
TCST: Data transmit with standard TCP protocol Client, The Heartbeat Packet And Register
Packet would be customed
Server Address: The data service center’s IP Address or domain name.
Server Port: The data service center’s listening port.
Device ID: The router’s identity number; This item is valid only when you choose UDP(DTU) or
TCP(DTU) .
Heartbeat Interval: The time interval to send heart beat packet. This item is valid only when you
choose UDP(DTU)
、
TCP(DTU) or TCST protocol type.
3.3.19 ZigBee Settings
1. According to the following conditions to set the configuration parameters for each ZigBee node ,
you can directly join the equipment to a complete ZigBee - Mesh networks
a, the same network number (range : 0 to 65535 )
2. Each module is assigned a unique node number, node number range is 0 ~ 65533. Of particular
note is a full Mesh Network Node (Master) is not necessary since the dominant role of the
node 0 node, the network can still operating run.
3. Open the device: For a complete Mesh Networks, the device can be opened arbitrary
commands.
4. Connection force: can be accessed by any node on all other devices in the network.