Add
:
J1-J3,3
rd
Floor,No.44,GuanRiRoad,SoftWare Park,XiaMen .361008.China
http
:
//www.fourfaith.com Tel
:
+86 592-6300326 6300325 6300324 Fax
:
+86 592-5912735
Node: As coordinator for the node type, node forced to '0 ' by default. When the node type for a
general node, node address range from 1 to 65533
NOTE: Coordinator to join the network, the network address is fixed to 0, other nodes can not be
set to 0.
The network address of the route and terminal equipment for non-zero,
65535 causes the system to assign a random address
Transparent transmission address
:
1) When the operating mode is selected as the protocol mode is invalid.
2) The master-slave mode, the destination address of the non - central node is fixed to the central
node (must be filled to 0);
3) Central node in broadcast mode, the router destination address is fixed at 65 535, the terminal
device without the need to set the target address.
Operating mode: setting the device to work in different work modes. Broadcast mode and
master-slave mode, the data transparently; protocol mode, the data with a format for transmission.
(Protocol mode, see Annex I)
ZigBee receiver timeout: Set the ZigBee receiver maximum wait time for the same packet, the unit
of time to the millisecond; restore the factory, this parameter defaults to 20
Enable ZigBee applications: whether ZigBee communication function, make sure to disable the
serial application before the application is enabled
Equipment transmission mode: This application supports communication between ZigBee and
serial port of the router and network module of the system conversion.
Note: when operating mode is selected as the protocol mode, the data forwarding mechanism
depending on the control of the data packet to determine
Protocol type: the type of agreement refers to the network transport protocol type. When the
communication conversion type selection network "or” the serial
+ network of the configuration, it must be configured.
Details:
1) UDP (DTU): ZigBee transfer UDP connections, add the functionality of a custom
application layer protocol, similar to the DTU.
2) The Pure the UDP: standard ZigBee turn UDP connections.
3) TCP (DTU): ZigBee to TCP client connections, add the functionality of a custom
application layer protocol, similar to the DTU.
4) The Pure the TCP: standard ZigBee transfer TCP client connection.
Registration package can be customized.