F8X14 Series User Manual

Trigger Type

Normally, IP MODEM always keeps online and always be ready for data transmission. But in

some circumstances, it’s important to reduce wireless data flow. To realize this function, the
software can makes IP MODEM into sleep state in idle time. When there is application data to
transmit, IP MODEM can be triggered online ready for data transmission. There are total five
methods to make IP MODEM online:

AUTO: IP MODEM always keeps online
SMSD: send a special short message to make IP MODEM online
CTRL: make IP MODEM online through a phone call to IP MODEM
DATA: send special serial data to make IP MODEM online
MIXD: the combination of SMSD, CTRL, DATA. IP MODEM will be online when meet one of

these three trigger methods.

AT Command:

AT+ACTI=xxxx

xxxx: one of the above trigger methods

Disconnect to Trigger Mode

If the Trigger Type is not

AUTO

and the Disconnect to Trigger Mode is enable, the modem will

go to trigger mode when the modem disconnect to the server.

AT Command:

AT+ISTRIGMODE=x

x = 0/1

0: Disable disconnect to Trigger Mode

1: Enable disconnect to Trigger Mode

Debug Level

Debug information is used to debug software when there is software problem.

0 --- no debug information output
1 --- simple prompt information output
2 --- detail debug information output

AT Command:

AT+DEBUG=x

x : the debug level value

Attention: Only there is some problem to the IP MODEM, It’s necessary to set this value

Содержание F8 14 Series

Страница 1: ...itable for the following model Model Product Type F8114 ZigBee GPRS IP MODEM F8214 ZigBee CDMA IP MODEM F8414 ZigBee WCDMA IP MODEM F8614 ZigBee EVDO IP MODEM Xiamen Four Faith Smart Power Technology Co Ltd Add Floor 11 Area A06 No 370 chengyi street Jimei Xiamen Tel 86 592 5907276 Fax 86 17750019379 Web en four faith com ...

Страница 2: ...4 19 V0 5 Draft Tracy zheng 2011 06 28 V0 6 Modification Tracy zheng 2011 07 14 V0 7 Modification Tracy zheng 2012 07 24 V0 8 Modification David 2013 03 20 V1 0 Modification David 2016 02 01 V1 1 Modify some parameters of Zigbee zxz 2017 10 10 V2 0 0 Change of company address LXP ...

Страница 3: ...ch as copy distribute reproduce the files etc but non commercial purpose downloaded or printed by individual all files shall be not revised and the copyright and other proprietorship notice shall be reserved are welcome Trademark Notice Four Faith 四信 are all registered trademarks of Xiamen Four Faith Communication Technology Co Ltd illegal use of the name of Four Faith trademarks and other marks o...

Страница 4: ...F8X14 Series User Manual ...

Страница 5: ...ation Connection 16 3 2 Configuration Introduction 16 3 3 Run the configure Tool IP Modem Configure exe 17 3 4 Re power IP MODEM 18 3 5 Configuration F8114 for example 18 3 5 1 Data Service Center Settings 18 3 5 2 IP MODEM Settings 21 3 5 3 Other Settings 26 3 5 4 Scheduled Power On Off Setting 30 3 5 5 ZigBee Setting 30 3 5 6 ModBus Setting 33 3 5 7 Port Setting 33 3 5 8 SMS Setting 34 3 6 SMS C...

Страница 6: ...when offline to make F8X14 IP MODEM is a kind of data terminal device that provides data transfer function by public cellular network and ZigBee network It adopts high powered industrial 32 bits CPU and embedded real time operating system It supports RS232 RS485 or RS422 and ZigBee port that can conveniently and transparently connect one device to a cellular network allowing you to connect to your...

Страница 7: ...ntenance interface High performance Support data transfer by cellular and ZigBee network Support TCP server and support multi TCP client connection optional Support double data centers one main and another backup Supply 5 I O channels compatible 2 pulse wave output channels 2 analog inputs and one pulse input counters Support multi data centers and it can support 5 data centers at the same time Su...

Страница 8: ...1xRTT 800MHz CDMA800 1900MHz optional CDMA450MHz optional Bandwidth 153 6Kbps TX power 30dBm RX sensitivity 104dBm F8314 Specification Item Content Cellular Module Industrial cellular module Standard and Band GSM850 900 1800 1900MHz GPRS EDGE Class 12 Bandwidth 236 8Kbps TX power GSM850 900 33dBm GSM1800 1900 30dBm RX sensitivity 106dBm F8414 Specification Item Content Cellular Module Industrial c...

Страница 9: ...v A 450MHz optional IS 95 A B CDMA2000 1xRTT Bandwidth 3 1Mbps down 1 8Mbps up TX power 23dBm RX sensitivity 104dBm ZigBee Specification Item Content ZigBee Chip Industrial ZigBee Chip Standard and Band IEEE 802 15 4 ISM 2 4 2 5GHz Indoor Urban Range 30m 90m With PA Outdoor RF Line of Sight Range 500m 2000m With PA Transmit Power 2 82mw 4 5dBm 100mw 20dBm With PA Bandwidth 250Kbps Receiver Sensiti...

Страница 10: ...on optional SIM UIM Standard 3V 1 8V user card interface 15KV ESD protection Power Terminal block interface reverse voltage and overvoltage protection Power Input Item Content Standard Power DC 12V 0 5A Power Range DC 5 35V Power Consumption Working States Power Consumption Communication 50 80mA 12VDC 115 150mA 5VDC Standby 20mA 12VDC 35mA 5VDC Sleep 8mA 12VDC 18mA 5VDC Timing Power Off 0 6mA 12VD...

Страница 11: ...F8X14 Series User Manual Operating Temperature 25 65ºC 13 149 Extended Operating Temperature 30 75ºC 22 167 Storage Temperature 40 85ºC 40 185 Operating Humidity 95 Non condensing ...

Страница 12: ... Forbid to install the IP MODEM when powered 2 2 Encasement List Name Quantity Remark IP MODEM host 1 2 4G ZigBee Antenna 1 Cellular Antenna 1 Power adapter 1 RS232 data cable 1 optional RS485 data cable 1 optional Manual CD 1 Certification card 1 Maintenance card 1 Table 2 1 Encasement List 2 3 Installation and Cable Connection Dimension unit mm ...

Страница 13: ...ntenna Screw the SMA male pin of the antenna to the female SMA outlet of the IP MODEM tightly Warning The antenna must be screwed tightly or the signal quality of antenna will be influenced User Interface Signal Definition Pin Number Signal Name Default Function Extensible Function 1 PWR Power input anode N A 2 GND Power Ground N A 3 GND Power Ground N A 4 RX RS232 RX N A 5 TX RS232 TX N A 6 A RS4...

Страница 14: ...mendatory cable is 28 16AWG The detail description of standard layout adapter and communication cables as is following Adapter Rating Output 12VDC 0 5A Cable Color Power Output Polarity Black White Alternate Anode Black Cathode RS232 Cable Cable Color Corresponding DB9 M Pin Number Brown Pin 2 Blue Pin 3 Black Pin 5 RS485 Cable Cable Color Signal definition Red RS485 A Black RS485 B ...

Страница 15: ...Light State Introduction Power ON IP MODEM is powered on OFF IP MODEM is powered off ACT BLINK Data is communicating OFF No data Online ON IP MODEM has logged on network OFF IP MODEM hasn t logged on network ZigBee ON ZigBee Transport data OFF No data Communication Interface RS232 Communication Interface RS485 F8X14 Terminal Block Interface User Device DB9M User Device 1 2 3 4 5 6 7 8 9 10 11 12 R...

Страница 16: ...configured through the shipped software tool It s necessary to have one PC to run this tool Extended AT command All the settings are configured through AT command so any device with serial port can configure it Before configuration with extended AT command you should make IP MODEM enter configure state The steps how to make IP MODEM enter configure state please refer to appendix The following desc...

Страница 17: ...correct serial port which connects to IP MODEM and the baud rate is 115200 with no parity then open the serial port If the button text is Close it shows the serial port now has been opened If the text is Open you should open the port first When the port opened the Output Info column will display Port COM1 Has Opened Please Re Power the IP MODEM Waiting IP MODEM Enter Configure State ...

Страница 18: ...ttings Settings on this page are the parameters related to Data Service Center DSC Data Center Number IP MODEM support two Data Service Center methods to transmit data Main and Backup IP MODEM always tries to connect with the Main DSC If fails to connect with Main DSC it will connect with Backup DSC at once Attention If no Backup DSC exists please configure the Backup DSC same as Main DSC Multi Da...

Страница 19: ...ated with a enter character Main Center Addr Port IP Address and Port of the Main DSC It s better to set the port greater than 1024 AT command of the Main DSC IP address or domain name AT IPAD xxx xxx The IP address or domain name AT command of the Main DSC port AT PORT xxx xxx The port value Backup Center Addr Port IP address and port of the Backup DSC AT command of the Backup DSC IP address or d...

Страница 20: ...ple Set IP address of center 3 as 166 111 8 238 and port 5001 the AT command is as following AT IPAD2 166 111 8 238 AT PORT2 5001 Main and Backup Center DNS Server When the DSC Internet access uses domain name It s necessary to set DNS server resolving the DSC domain name When the Data Center Number is 1 Main and Backup Center DNS Server is used to resolve the Main center and Backup center corresp...

Страница 21: ...S CSD Dial up applications TTRN Heartbeat packet with UDP protocol Data transmission with TCP protocol TLNT IP MODEM work as a telnet client LONG Heartbeat packet with UDP protocol Data transmission with TCP protocol It can transmit at most 8192 bytes data one time through extra application protocol LNGT Heartbeat with UDP protocol Data transmission with TCP protocol It can transmit at most 8192 b...

Страница 22: ...rial data to make IP MODEM online MIXD the combination of SMSD CTRL DATA IP MODEM will be online when meet one of these three trigger methods AT Command AT ACTI xxxx xxxx one of the above trigger methods Disconnect to Trigger Mode If the Trigger Type is not AUTO and the Disconnect to Trigger Mode is enable the modem will go to trigger mode when the modem disconnect to the server AT Command AT ISTR...

Страница 23: ...pbit 8N2 8 Databit No parity 2 Stopbit 8E2 8 Databit Even parity 2 Stopbit 8O2 8 Databit Odd parity 2 Stopbit 7O2 7 Databit Odd parity 2 Stopbit 7E2 7 Databit Even parity 2 Stopbit 7N2 7 Databit No parity 2 Stopbit AT Command AT SERMODE xxx xxx one of the above serial mode Communication Baudrate 110 110 bps 300 300 bps 600 600 bps 1200 1200 bps 2400 2400 bps 4800 4800 bps 9600 9600 bps 14400 14400...

Страница 24: ...ly valid when you set Data Center Number as 1 In this mode IP MODEM will switch to backup center when main center have problems If this item is set to 1 IP MODEM will check whether the main center work fine timely When it detects the main server work fine it will return back to the main server at once AT Command AT RETMAIN x x 0 or 1 Device ID The identity number of IP MODEM the value should be 8 ...

Страница 25: ...ister String This item is only valid when the WorkMode is TCST It s the self defined register string It can be empty the maximum length is 70 bytes AT Command AT CONNRGST xxx xxx self defined register string Custom Heartbeat String This item is only valid when the WorkMode is TCST It s the self defined heartbeat string It can be empty the maximum length is 70 bytes AT Command AT LINKRGST xxx xxx s...

Страница 26: ...nter Reconnect Time Interval AT Command AT RDLWT xxx xxx the sleep time until next retry Transfer meanning 0 Yes enable transfer meaning 1 No disable transfer meaning This item is only valid when the WorkMode is PROT If this item is set to 0 IP MODEM will transfer meaning to 0xfd and 0xfe To know detail transfer meaning method please refer IP MODEM Transfer Meaning Explanation In the PROT work mod...

Страница 27: ...F8514 cmnet null 98 1 F8614 null card 777 AT Command of APN AT APN xxxx xxxx access point name AT Command of Username AT USERNAME xxx xxx username AT Command of Password AT PASSWORD xxx xxx password AT Command of Call Center AT CENT xxx xxx call center phone number of ISP SMS Center Your local SMS center number AT Command AT SMSC xxx xxx your local SMS center number Heartbeat Interval Time interva...

Страница 28: ...s SMSD or MIXD IP MODEM will keeps in idle state until it receives the trigger short message Then it will connect to the center AT Command AT SMSDPSWD xxx xxx SMS content to trigger IP MODEM online Data Trigger Password This item is valid only when the Trigger Type is DATA or MIXD IP MODEM will keeps in idle state until it receives the trigger on data then it will connect to the center It will ret...

Страница 29: ...he configured reconnect interval AT Command AT MCONTIME xxx xxx reconnect time interval unit is second SMS Configure The SMS configure function should be set Enable if you want to configure the para of IP MODEM by means of sms The specific format of the configure message is in the part of 3 6 SMS Config Setting AT Command AT SMSCF x x 0 1 0 Disable SMS configure function 1 Enable SMS configure fun...

Страница 30: ...e to setup every node with the following common configurations a An identical RF Channel b An identical MAC Layer Network Identifier from 0 to 65531 65535 Random 2 Now provision a unique MAC Node Identifier into each module The unique Node Identifier can be selected from the range of 0 to 65531 65535 Random Note that Node 0 in a full mesh network does not have any supremacy over other nodes any mo...

Страница 31: ...work AT Command AT PID n n 0 65531 65535 Random Transparent Addr Setting AT Command AT TID n n 0 65531 65535 Broadcast Command AT TID 65535 means the message transfer with broadcasting mode Workmode Setting Sets of Transfer mode of device The information of Trans mode is Transparent transmission API mode has protocol format ...

Страница 32: ...erial port 2 COM to Zigbee data from serial port will transfer to Zigbee module 3 GPRS to COM data from remote center will transfer to serial port 4 COM to GPRS data from serial port will transfer to remote center 5 Zigbee to GPRS data from Zigbgee module will transfer to remote center 6 GPRS to Zigbee data from remote center will transfer to Zigbee module AT Command AT ZDATCHAN dir Tab3 1 zigbee ...

Страница 33: ... RTU Modbus address ModBus address represents the MODBUS device address of IP MODEM itself The server will find the modem on the basis of this address Modbus address will work when the Modbus Work mode is Network RTU AT Command AT MBADDRESS x x 1 247 3 5 7 Port Setting Digital quantity work mode The IP MODEM has 3 digital quantity ports in all IO1 IO2 IO3 These ports are corresponding with pin 8 9...

Страница 34: ...s the MODBUS commond when the analog quantity work mode is One time colletion and the Modbus work mode is Network RTU AT Command AT ADCMODEn x n 1 2 1 IO4 Pin11 2 IO5 Pin12 x 0 1 0 Disable 1 One time colletion 3 5 8 SMS Setting SMS Sending Number If the network connection fail IP MODEM will send the data which come from serial port As the content of the messages to the SMS Sending number This func...

Страница 35: ...in the porcess of monitoring to the Industrial control device AT Command AT HEXSMS x x 0 1 0 Common SMS 1 HEX SMS SMS backup Function SMS backup function If the network connection fail IP MODEM will send the data which come from serial port in messages to the SMS Sending number AT Command AT OPENSMSBCKP x x 0 1 0 Disable SMS backup Function 1 Enable SMS backup Function UDP mode lost package instru...

Страница 36: ...and remove the AT Multiple comomds are divided by semicolons Example 123456 IPAD 120 42 46 98 PORT 5007 Comment password 123456 ip address 120 42 46 98 port 5007 3 7 Functions Clear Output Clear the output information Version Display Show the software and hardware version Signal Value Display current wireless signal value Factory setting Restore to factory settings Show Config Show current IP MODE...

Страница 37: ...Load Config Load settings from a previous saved configure file 3 8 Work State Switch This tool can work in two states Config and Communication Config This state is used to configure parameters of IP MODEM Communication This state is used as a common serial communication tool Reboot Enter Communication State This function button is used to reboot IP MODEM and make the software switch to Communicati...

Страница 38: ... zigbee net please set their device type as Router or Terminal equipment The data flow from PC to F8114 zigbee Router through F8914 zigbee Coordinator is PC serial port 2 data F8914 serial port F8914 s Zigbee protocol stack encapsule the data send to Zigbee net Zigbee net to F8114 The data flow from F8114 to PC through F8914 zigbee Coordinator is the reverse transmission process above The data flo...

Страница 39: ... Router is the reverse transmission process above 4 2 Testing steps 1 Run the Demo on the Server click Start button on toolbar The demo is listening on port 5007 2 Config the para of IP MODEM the data server s ip address is 120 42 46 98 port is 5007 shown in the red frame below ...

Страница 40: ...5 Broadcast Physical channel 15 Trans Type choose all the direction Configure another Zigbee device For example F8914 as Router in the zigbee net PAN ID 10 Physical channel 15 Debug level 1 as shown in the red frame below 4 Close the config tools of F8914 and IP MODEM run two IP Modem Configure Tool on the ...

Страница 41: ...e IP Modem Configure Tool of COM6 and the Online light of F8914 is on then power on the IP MODEM as Zigbee Router in this testing is F8114 5 Confirmed that the IP Modem has installed an usable SIM card then power on the IP Modem again If the IP Modem has connected with the Server it will output the info in the red frame below The Ip Modem online will appear on the DEMO The ID number of F8114 is 74...

Страница 42: ...F8X14 Series User Manual 6 DEMO has shown the IP MODEM online as shown in the blue frame below The ID number of IP MODEM online is 74736574 F8114 has logined on the Server successfully ...

Страница 43: ...ed frame below comes from data server Demo The data F8914 in the blue frame below comes from F8914 Zigbee Coordinator 8 DEMO has sended Server to F8114 and F8914 as show in the yellow frame below The data F8114 in the red frame below comes from F8114 Zigbee Router The data F8914 in the blue frame below comes from F8914 Zigbee Coordinator ...

Страница 44: ...how in the yellow frame below The data F8114 in the red frame below comes from F8114 Zigbee Router The data Server in the blue frame below comes from data server DEMO 10 In this testing it has shown that the data server DEMO F8114 and F8914 can communicate with the two others ...

Страница 45: ...with the Windows XP Hyper Terminal 1 Press Start Programs Accessories Communications Hyper Terminal 2 Input connection name choose OK 3 Choose the correct COM port which connect to IP MODEM choose OK 4 Configure the serial port parameters as following choose OK Bits per second 115200 Data bits 8 Parity None ...

Страница 46: ...l Stop bits 1 Flow control None 5 Complete Hyper Terminal operation It runs as following 6 Re power IP MODEM put mouse focus on the Hyper Terminal and press s key continuously until IP MODEM enter configure state as following ...

Страница 47: ...F8X14 Series User Manual 7 IP MODEM has entered configure state you can configure the parameters through AT command ...

Страница 48: ... used to ensure packet integrity This field is computed as an XOR of all the bytes in the message starting with LEN field and through the last byte of data The following is a sample code FCS calculation unsigned char calcFCS unsigned char pMsg unsigned char len unsigned char result 0 while len result pMsg return result Attention The data content should be send with little endian the lowest byte co...

Страница 49: ...3 Data State 1 00 00 success Others error FCS 1 64 Frame check sequence 2 Data receive command Receive Data Fields Sub field Offset Example Description SOF 1 FE 0xFE Length 1 06 The length of data Command Recive 2 44 5F Fixed to 44 5F Data Source 2 10 0E The sender node address little endian Content 80 41 41 41 41 The content to be recived FCS 1 03 Frame check sequence ...

Отзывы: