Hardware installation
Changing FortiSwitch-5003B SW2 switch settings
FortiSwitch-5003B System Guide
01-400-134822-20120216
19
http://docs.fortinet.com/
Figure 6: Factory default shelf manager mode setting for SW2
By default a FortiSwitch-5003B board will not start up if the board is installed in a chassis
that does not contain a shelf manager or that contains a shelf manager that is not
operating. Before installing a FortiSwitch-5003B in a chassis that does not contain an
operating shelf manager you must change the SW2 switch setting to that shown in
Figure 7
.
Figure 7: Standalone mode setting for SW2
In all cases you should confirm that you have the correct SW2 setting before installing the
board in a chassis.
To change or verify the SW2 switch setting
To complete this procedure, you need:
• A FortiSwitch-5003B board
• A tool for changing the SW2 switch setting (optional)
Table 11: FortiSwitch-5003B SW2 settings
Chassis
Correct
SW2
Setting
Result of wrong jumper setting
FortiGate-5140B or 5060 or a
ATCA chassis with a compatible
operating shelf manager (factory
default shelf manager mode).
Shelf manager cannot find
FortiSwitch-5003B board. No shelf
manager information about the
FortiSwitch-5003B board available.
Any ATCA chassis without an
operating shelf manager
(standalone mode).
FortiSwitch-5003B board will not
start up.
Factory Default
(Requires Shelf
Manager)
ON
SW2
34
2
1
ON
SW2
34
2
1
Standalone Mode
(No Shelf Manager)
ON
SW2
34
2
1
ON
SW2
34
2
1
If the shelf manager in a FortiGate-5000 series chassis is missing or not functioning,
FortiSwitch-5003B boards with factory default SW2 settings will not start up.