FortiSwitch-5003B system
Front panel components
FortiSwitch-5003B System Guide
01-400-134822-20120216
13
http://docs.fortinet.com/
Entering the following commands from the FortiSwitch-5003B CLI will disable the slot-7,
slot-12 and slot-1/2 fabric channel interfaces. You do not have to disable f8/slot-1/2
interface if the active connection is set to F8.
config switch fabric-channel physical-port
edit slot-7
set status down
next
edit slot-12
set status down
next
edit f8/slot-1/2
set status down
next
end
Base channel interfaces
Front panel connectors
Table 9: Base channel interfaces and network activity LEDs
Interface Name
Description
Front
Panel
CLI*
SH1 and
SH2
sh1
and
sh2
Interface for backplane connection between FortiSwitch-5003B
board and shelf manager 1 (SH1) or shelf manager 2 (SH2).
This LED may not be lit even if a shelf manager is present if the
shelf manager is configured to use its front panel interface.
1/2
slot-
1/2
Interconnection interface between base channels 1 and 2. This
LED is lit only if a chassis contains two FortiSwitch-5003B
boards in slots 1 and 2.
3 to 14
slot-3
to
slot-14
Base channel connection to FortiGate-5000 boards in chassis
slots 3 to 14.
B1 and B2
b1 and
b2
Front panel SFP+ base channel interfaces B1 and B2.
Use these interfaces to connect your network to the base
channel, to connect base channel 1 to base channel 2, or to
connect a base channel on one chassis to a base channel on
another chassis.
* You can configure settings for FortiSwitch-5003B base interfaces from the
FortiSwitch-5003B CLI. The CLI columns show the names of the interfaces as they
appear on the FortiSwitch-5003B CLI.
Table 10: FortiSwitch-5003B connectors
Connector Type
Speed
Protocol
Description
CONSOLE
RJ-45
9600 bps
8/N/1
RS-232
serial
Serial connection to the
command line interface.
USB
USB
Not used.