Deployment
This example shows the preliminary positions of base stations A, B, C, D, E and F. You will need to configure the
corresponding sync level for each base station according to these positions. Start with the base station for which a
subsequent change would mean the greatest effort, this will be the base station with sync level 1. Then move outwards
from sync level to sync level.
Here we have set the following:
Sync Level 1
: Base station
A
Sync Level 2
: Base station
B
,
C
and
E
Sync Level 3
: Base station
D
and
F
For the office room hotspot, two additional base stations have been placed in parallel for optimal coverage and channel
connections.
In this example, the other hotspot is the After-sales Department. Two base stations service this area, base station
E
is
outside of the room but is behind a glass wall, which has little effect on the DECT signal.
Check to ensure that these placements are correct by taking measurements, as described in the Measuring signal
strength section.
Measuring signal strength
Taking measurements can help determine where you may need to put additional base stations to have handover and
synchronization.