![Fortinet FortiFone-FON-D72 Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/fortinet/fortifone-fon-d72/fortifone-fon-d72_user-manual_2321742020.webp)
Deployment
Measuring
point
Base A
Base B
Base C
Base D
Base E
Base F
11
-57
-59
-55
12
-60
-50
13
-53
14
-58
15
-35
-52
16
-34
-50
17
-53
-40
18
-52
19
-40
Measuring signal strength
Measure the signal strength transmitted from the measuring base station and the planned position of the neighboring
base station. This measurement is used to ensure that sufficient synchronization overlap is guaranteed.
For the base stations to be able to synchronize, we recommend that the signal value between the base stations be kept
above -85 dBm.
For this procedure:
1.
Leave the first-level base station at the planned position. Take the measuring handset to the planned position of
the second-level base station.
2.
Check to ensure that the RSSI is within -85 dBm and the frame quality is at 100%.
3.
Record this within your measurement log.
4.
Measure for all planned positions of base stations that will synchronize with the first-level base station.
The following image presents an example of planned base station positions:
FortiFone FON-D72 User Guide
20
Fortinet Technologies Inc.
Содержание FortiFone-FON-D72
Страница 1: ...FortiFone FON D72 User Guide...