You can use any brand of hard disk to replace a failed hard disk. However, you
must ensure that the hard disk size is the same size as the remaining working
drives. Using a smaller drive will affect the RAID setup. The FortiAnalyzer unit will
reconfigure the RAID to the smaller drive, potentially causing data loss.
Table 6: FortiAnalyzer-400 disk drive configuration.
Table 7: FortiAnalyzer-800 disk drive configuration.
To swap a FortiAnalyzer-400 or FortiAnalyzer-800 hard disk
1
Go to
System
>
Config
>
RAID
.
The web-based manager displays which hard disk has failed. A trash can icon
appears next to the failed disk drive.
2
Select Remove for the failed hard disk.
A message displays indicating it is safe to remove the disk from the drive.
3
Remove the hard disk from the drive bay on the FortiAnalyzer unit
• On the FortiAnalyzer-400, open the faceplate, remove the screws for the drive
and pull out the drive.
• On the FortiAnalyzer-800, pull open the face place, unlock the drive and pull
out the drive.
4
Insert the new hard disk into the empty drive bay on the FortiAnalyzer unit,
reversing the steps above.
5
Select Return from the web-based manager.
The FortiAnalyzer disk controller will scan the available hard disks and update its
information with the new hard disk.
6
Select Add to add the hard disk to the RAID array.
The FortiAnalyzer unit rebuilds the RAID array with the new hard disk.
Hot swapping the FortiAnalyzer-2000 and
FortiAnalyzer-4000/4000A
The following diagram indicates the drive number and their location in the
FortiAnalyzer unit when you are looking at the front of the unit. Refer to this
diagram before removing the disk drive to ensure you remove the correct one.
You can use any brand of hard disk to replace a failed hard disk. However, you
must ensure that the hard disk size is the same size as the remaining working
drives. Using a smaller drive will affect the RAID setup. The FortiAnalyzer unit will
reconfigure the RAID to the smaller drive, potentially causing data loss.
Note:
Only perform a hot swap with a RAID setting of either 1 or 5. Hot swapping on any
other RAID settings will result in data loss.
Drive 1 (p1)
Drive 2 (p2)
Drive 3 (p3)
Drive 4 (p4)
Drive 1
Drive 2
Drive 3
Drive 4
Содержание FortiAnalyzer-100A
Страница 1: ...www fortinet com FortiAnalyzer Version 3 0 MR3 A D M I N I S T R A T I O N G U I D E...
Страница 10: ...FortiAnalyzer Version 3 0 MR3 Administration Guide 10 05 30003 0082 20060925 Contents...
Страница 76: ...FortiAnalyzer Version 3 0 MR3 Administration Guide 76 05 30003 0082 20060925 Blocked Devices Devices...
Страница 88: ...FortiAnalyzer Version 3 0 MR3 Administration Guide 88 05 30003 0082 20060925 Log rolling Logs...
Страница 94: ...FortiAnalyzer Version 3 0 MR3 Administration Guide 94 05 30003 0082 20060925 Log rolling Content archive...
Страница 138: ...FortiAnalyzer Version 3 0 MR3 Administration Guide 138 05 30003 0082 20060925 Output Alerts...
Страница 150: ...FortiAnalyzer Version 3 0 MR3 Administration Guide 150 05 30003 0082 20060925 Log rolling Network Analyzer...
Страница 156: ...FortiAnalyzer Version 3 0 MR3 Administration Guide 156 05 30003 0082 20060925 Reports Vulnerability scan...
Страница 161: ...www fortinet com...
Страница 162: ...www fortinet com...