FORTEZA JSC
FORTEZA FMC 24 (50m, 100m, 200m)
Please visit our internet sites:
2.4.1.2. Direct Rx and Tx against each other using a sight leaf situated on the antennas
sides.
2.4.1.3. Tighten the bolts 12 and 9 of Rx and Tx;
2.4.2. Main adjustment of Tx and Rx
2.4.2.1. Open the cover 6 of Rx (fig.1.2).
TX transmitter
RX receiver
Fig. 2.6
2.4.2.2. Channels set up.
The receiver and transmitter should be adjusted to the same
signal frequency. It is necessary to set the different channels to nearby detection zones.
FREQ CH switches
Note: You can check which channel receiver and transmitter in operation by
switches FREQ CH position (table 9.1.)
2.4.2.3
.
Check the right connection of supply circuits and output circuits of the
detector. Switch ON the power supply.
2.4.2.4. When power is supplied to detector Rx and TX units, the “LED” blinking
indicates the frequency channel.
TX - “LED” blinks once per 2 sec it is means that power is connected and it is
acceptable range.
RX - after 1-2 minutes afters tuning the power supply, check the status of “LED”
indicator: the indicator should be off, that informs, detector is in standby mode.
2.4.2.5. After 3-5 sec RX “LED” is switch off which means that detector is in
operation mode.
Note:
In situation, if the indicator Rx continuously on, periodically and briefly goes
out or lights up-determine the problem and correct it using table 4.1
2.4.2.6.
Aligning is performed incrementally and consists of a set of repetitive actions.
The alignment can be started with both transmitter or receiver. In the alignment mode, the
detector switch, when you press and hold down the button, "AGC" on receiver. The indicator