FORTEZA JSC
FORTEZA FMC 24 (50m, 100m, 200m)
Please visit our internet sites:
2.5.3.3.
After choosing the proper com port, the communication with the device starts
automatically.
Fig.2.12
2.5.3.4.
In the left side of the screen you can see the current setting parameters. They
have the following meaning:
Detector:
Information about detectors model
FMC,
operation frequency
10
(10.525
GHz), operation length up to
(100m)
Version:
Version of software
Output type:
Relay (normal close contact)
Unit ID:
It means the frequency modulation of the receiver. The transmitter and
receiver should be on the same frequency modulation (1 ~ 4). Frequency modulation
changing using the switches (see 9.3.1)
Mode:
‘Normal’ or ‘Alarm’ mode of the detector. There should be ‘Normal’ before
fine tuning (calibration). ‘Normal’ means no alarm; ‘Alarm’ means alarm state.
Zone length:
The currently selected operation distance for the detector. It is really
important to choose the proper operation distance.
Note: It is used only in Setup Method: AUTO
Note: If the zone length is not the real distance, there might be higher false alarm
rate or poor sensitivity.
Setup method:
The currently selected setup method. You can choose “Auto, ‘Manual’,
SPECIAL 1 or SPECIAL 2 setup modes. In ‘Manual’ setup you can set sensitivity, in ‘Auto’
setup you can change ‘Zone length’.
In most of the cases ‘Auto’ setting is recommended.