Fortek Security Systems
Tel: 1-800-505-6476
www.forteksecurity.com
Fax: 1-866-655-6342
4
1 - Enroll a single credential
A)
Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B)
Enter the 4 digit security password – factory default:1234. The green light will blink twice if
the correct password was entered.
C)
Press key number one "1" to enter to the "enroll single credential mode", the green light will
blink once and remain on to indicate that the new credential has to be presented onto the
reader
D)
Present the new credential over the proximity reader, if the operation was successful the light
on the reader will blink twice, turning from red to green, indicating the credential was
successfully incorporated into the system. The system will exit the programming mode
automatically.
Note 1:
The last 4 digits printed on the credential is automatically stored into the system, allowing
future deletion or replacement if necessary. (Software provided to keep track of users and assigned
credentials)
Note 2:
Upon attempt to enrolling an already existent credential the light on the reader will remain
green for 10 seconds and the controller will emit a warning beeping 5 times.
2- Enroll multiple credentials
A)
Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B)
Enter the 4 digit security password – factory default:1234. The green light will blink twice if
the correct password was entered.
C)
Press key number one "0" to enter to the "enroll multiple credentials mode", the green light
will blink once and remain on to indicate that new credentials have to be presented on the
reader.
D)
Present the new credentials onto the reader consecutively, after each credential is presented,
the light on the reader will blink twice, turning from red to green indicating the credential was
successfully incorporated into the system.
E)
To finish the operation press and hold the Escape key "ESC" until double beep is heard, the
orange and green light will be turn off indicating that the system exited the programming mode.
Note 1
: The last 4 digits printed on the credentials are automatically stored into the system,
allowing future deletion or replacement if necessary. (Software provided to keep track of users and
assigned smart keys)
Note 2
: Upon attempt to enrolling an already existent credential the light on the reader will remain
green for 10 seconds and the controller will emit a warning beeping 5 times.
Keypad Instructions - Operational Mode 1