Fortek Security Systems
Tel: 1-800-505-6476
www.forteksecurity.com
Fax: 1-866-655-6342
17
1 – Enroll/Edit a single credential
A)
Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B)
Enter the 4 digit security password – factory default:1234. The green light will blink twice if the
correct password was entered.
C)
Press key number one "1" to enter to the "enroll single credential mode", the green light will
blink once and remain on to indicate that the new credential has to be presented on the reader
D)
Enter the number of door you want to activate the credential on:
Enter “1” to enroll the credential to unlock door number 1
Enter “2” to enroll the credential to unlock door number 2
Enter “3” to enroll the credential to unlock both doors
Present the new credential over the reader (any of the two readers), if the operation was
successful the light on the reader will blink twice, turning from red to green, indicating the
credential was successfully incorporated into the system. The system will exit the programming
mode automatically.
Note 1:
The last 4 digits printed on the credential are automatically stored into the system,
allowing future deletion or replacement if necessary. (Software provided to keep track of users and
assigned credentials)
Note 2:
Upon attempt to enrolling an already existent credential with the same authorized door
the light on the reader will remain green for 10 seconds and the controller will provide a warning
beeping 7 times.
2- Enroll/Edit multiple credentials
A)
Press and hold the Escape key "ESC" until a double beep is heard. The orange light will remain
on to indicate you have entered into the programming mode.
B)
Enter the 4 digit security password – factory default:1234. The green light will blink twice if the
correct password was
entered.
C)
Press key number one "0" to enter to the "enroll multiple credentials mode", the green light
will blink once and remain on to indicate that new credentials have to be presented on the
reader.
D)
Enter the number of door you want to authorize the access to:
Enter “1” to enroll the credentials to authorize unlocking door number 1
Enter “2” to enroll the credentials to authorize unlocking door number 2
Enter “3” to enroll the credentials to authorize unlocking both doors
Present the new credentials over the reader consecutively, after each credential is presented, the
light on the reader will blink twice, turning from red to green indicating the credential was
successfully incorporated into the system, if the credential was already in the system and it was set
with a different authorized door/s the modification will be made.
Keypad Operation Instructions – Operational Mode 3