You eliminate the failure as follows:
1. Check all feed-conducting components from the mixer up to the mixer drain valve or from
the mixer up to the teat for clogs and remove them.
The hose that goes from the mixer drain valve to the drain shaft may not be
lengthened.
2. Check the feeding pump.
•
Confirm
Mixer emptying warning
by choosing
.
•
Confirm
Feeding pump: start?
by choosing
.
•
The mixer is evacuated.
3. Check the mixer drain valve if your automatic feeder has one.
•
Confirm the
Mixer emptying warning
by choosing
.
•
Confirm
Mixer drain: open?
by choosing
.
•
The mixer is evacuated.
4. Check the bar electrode.
•
Visually check the bar electrode for deposits.
5. Fill and drain the mixer.
•
Confirm the
Mixer emptying warning
by choosing
.
6. Confirm
Water HE start?
by choosing
.
•
The mixer fills up with water.
7. Confirm
Mixer: drain?
by choosing
.
The mixer is drained.
Once the failure is eliminated, the message
Delete failure?
appears in the display. Confirm
Delete failure?
by choosing
.
If this does not correct the error, you must contact a service technician immediately.
Содержание TAK5-CH2-25
Страница 2: ......
Страница 6: ...6 Table of contents ...
Страница 31: ...Operating the automatic feeder 31 4 2 1 The 15 key hand terminal 1 Keypad 2 Auto LED 3 Display ...
Страница 126: ...126 Failures and warnings ...
Страница 129: ...Appendix 129 9 Appendix 9 1 Feeding 9 1 1 Standard feeding plans 9 1 1 1 Group A ...
Страница 130: ...130 Appendix 9 1 1 2 Group B 9 1 1 3 Group C ...
Страница 131: ...Appendix 131 9 1 1 4 Group D ...
Страница 132: ...132 Appendix 9 1 1 5 Template for individual feeding plan ...
Страница 133: ...Appendix 133 9 1 2 Basic principle of interval feeding ...