Forno Classico Colosso 100 Скачать руководство пользователя страница 8

   

8

   

Traditional Series 

Installation and Operation Manual

An ongoing program of product improvement may require us to change
specifications without notice. 

WS-TS Installation Manual, 

Revised September 2016.                          Doc no: M0119.04

[email protected]

 

or visit 

woodstone-corp.com

Wood Stone Corporation

1801 W. Bakerview Rd.
Bellingham, WA 98226  USA

Toll Free  800.988.8103
Tel  360.650.1111
Fax  360.650.1166

9

!

WARNING:

 Installation and servicing of this product could expose you to glasswool/ceramic 

fibers as well as calcium silicate dust. ALWAYS WEAR RESPIRATORY AND EYE PROTECTION 
WHEN INSTALLING OR SERVICING THIS APPLIANCE. Please read this entire manual before 
you install the oven. Failure to follow instructions may result in property damage, bodily 
injury or even death. Contact your local building or fire officials about restrictions and 
installation inspection in your area.

INSTALLATION CLEARANCES

CLEARANCES

1.

 

The Traditional Series oven is designed to accommodate field application of tile, stucco or other NON-COMBUSTIBLE finishes. 
The Wood Stone Traditional Series oven must have a

 

minimum 1" clearance to combustibles from all sides, and 14" 

clearance to combustibles from the top 

(see INSTALLATION CLEARANCES section on next page). If building a facade 

that will contact the oven, use completely non-combustible materials*. Please note that standard Drywall (or Sheetrock) is 
considered a combustible.

2.

 

If enclosing the oven, any facade materials 6" to either side of the oven doorway and above must be constructed of non-
combustible building materials. All materials in direct contact with, or attached to the oven body, must be non-combustible.

3.

 

Install this oven only on a non-combustible floor surface. (Cet appareil doit être installé sur une surface de plancher non-
combustible.) The non-combustible floor surface should extend 36" out in front of the oven, and extend 30" to either side of 
the oven doorway.

*When NON-COMBUSTIBLE building materials contact the body of the appliance, the clearances to combustibles are transferred 
to those non-combustibles.

NOTICE: 

Only non-combustible materials may be applied directly to the oven.

IF THIS OVEN IS NOT PROPERLY INSTALLED A FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THESE 
INSTALLATION INSTRUCTIONS. A MAJOR CAUSE OF OVEN RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED 
CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF UTMOST IMPORTANCE THAT THIS OVEN BE 
INSTALLED ONLY IN ACCORDANCE WITH THESE INSTRUCTIONS.

WARNING:

 DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIAL.

PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL THE OVEN. FAILURE TO FOLLOW INSTRUCTIONS MAY 
RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH. CONTACT YOUR LOCAL BUILDING OR FIRE 
OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA.

 

 

   

   

   

INSTALLATION   CLEARANCES

   

Commercial   Oven   Series

   

Installation

,   Operation   &   Maintenance

   

Forno Classico LLC                                     

   

Phone:

 

(805) 8

95

-

2626 

 

53

 

Aero Camino                                             [email protected]

 

Goleta, CA 93117 USA                                  www.fornoclassico.com

 

Содержание Colosso 100

Страница 1: ...OLOSSO GO 80 32 COLOSSO GO 100 40 COLOSSO GO 120 48 COLOSSO GO 140 55 COLOSSO GO 160 63 COLOSSO SERIES Gas Fire Model ITALIAN BRICK OVEN Forno Classico LLC Phone 805 895 2626 53 Aero Camino info forno...

Страница 2: ...WARNING 6 7 INSTALLATION CLEARANCES 8 9 OUTDOOR INSTALLATION 10 GAS SPECIFICATIONS 11 12 VENTING 13 15 LIGHTING THE OVEN 16 17 FLAME CONTROL 18 GAS OVEN MANTENENS 19 CURING THE OVEN 20 COOKING ENVIRO...

Страница 3: ...OSSO GO 100 40 COLOSSO GO 120 48 COLOSSO GO 140 55 COLOSSO GO 160 63 GAS FIRED GAS WOOD COMBINATION MODELS ADDITIONAL COPIES AVAILABLE UPON REQUEST Oven Model Commercial Oven Series Colosso Forno Clas...

Страница 4: ...jury or even death Contact your local building or fire officials about restrictions and installation inspection in your area IMPORTANT It is recommended that this oven be installed maintained and serv...

Страница 5: ...0119 04 info woodstone corp com or visit woodstone corp com Wood Stone Corporation 1801 W Bakerview Rd Bellingham WA 98226 USA Toll Free 800 988 8103 Tel 360 650 1111 Fax 360 650 1166 Wood Stone s gas...

Страница 6: ...en Model Approximate Shipping Weight Minimum Fork Length Required Required Forklift Capacity Pallet Jack Capacity Colosso 65 1 200 lbs 4 3 000 lbs 2 000 lbs Colosso 80 2 800 lbs 4 4 000 lbs 3 000 lbs...

Страница 7: ...e sure to use a forklift rated and forks the minimum length as shown in Appendix A Fork extensions must be used so the forks extend through to the opposite side of the stand The oven is very top heavy...

Страница 8: ...2 If enclosing the oven any facade materials 6 to either side of the oven doorway and above must be constructed of non combustible building materials All materials in direct contact with or attached t...

Страница 9: ...arry an CSA Sanitation listing The oven interior only is CSA listed to NSF ANSI Standard 4 Surfaces of the oven meant to be left exposed after facade installation have been evaluated for sanitation an...

Страница 10: ...10 OUTDOORS INSTALLATIONS Commercial Oven Series Installation Operation Maintenance Forno Classico LLC Phone 805 895 2626 53 Aero Camino info fornoclassico com Goleta CA 93117 USA www fornoclassico co...

Страница 11: ...11 GAS SPECIFICATIONS Commercial Oven Series Installation Operation Maintenance Forno Classico LLC Phone 805 895 2626 53 Aero Camino info fornoclassico com Goleta CA 93117 USA www fornoclassico com...

Страница 12: ...s or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 or The Natural Gas installation Code CAN CGA B149 1 as applicable including The appliance and its individual shutoff valv...

Страница 13: ...lid fuel ovens Submit your venting plans to your local authorities before proceeding with your installation as there may be additional requirements in your area There are two venting options VENTING O...

Страница 14: ...not be combined with exhaust systems serving other non solid fuel equipment This model is rated as solid fuel equipment and must be vented as such VERY IMPORTANT FORNO CLASSICO RECOMMENDS THAT YOU CO...

Страница 15: ...R VENTING SYSTEM CHECK WITH LOCAL AUTHORITIES FOR SPECIC CODE REQUIRMENTS VENTING CONT Commercial Oven Series Installation Operation Maintenance Forno Classico LLC Phone 805 895 2626 53 Aero Camino in...

Страница 16: ...16 LIGHTING THE OVEN Commercial Oven Series Installation Operation Maintenance Forno Classico LLC Phone 805 895 2626 53 Aero Camino info fornoclassico com Goleta CA 93117 USA www fornoclassico com...

Страница 17: ...17 LIGHTING THE OVEN Commercial Oven Series Installation Operation Maintenance Forno Classico LLC Phone 805 895 2626 53 Aero Camino info fornoclassico com Goleta CA 93117 USA www fornoclassico com...

Страница 18: ...80 F Cooking Flame After introducing the pizza product into the oven visually raise the flame to approximately 3 inches higher than the Holding Flame Return the Flame Height Control Knob to the Holdin...

Страница 19: ...no Classico website under Tools Accessories NEVER PLACE ANYTHING IN OR ABOVE THE RADIANT FLAME NEVER SWEEP DEBRIS INTO THE RADIANT BURNER THIS CAN CAUSE THE BURNER TO CUT OUT DAMAGE BURNER COMPONENTS...

Страница 20: ...AY 3 DAY 4 6 10 15 PILOT CURING THE OVEN Commercial Oven Series Installation Operation Maintenance Forno Classico LLC Phone 805 895 2626 53 Aero Camino info fornoclassico com Goleta CA 93117 USA www f...

Страница 21: ...and a maintenance flame that reaches just up the side of the oven but not across the top The door may be placed at a slight angle on the shelf in front of the arch If black soot accumulates on the ov...

Страница 22: ...dishwasher or sink Follow exhaust hood manufacturer s recommendations or NFPA 96 requirements for inspection maintenance and cleaning Seek out a qualified chimney sweep or exhaust duct service techni...

Страница 23: ...ipped to FC LLC in compliance with FC LLC s shipping instructions freight pre paid with the RMA number displayed on the outside of the shipping container Customer will be responsible for damage occurr...

Страница 24: ...going program of product improvement may require us to change specifications without notice Forno Classico LLC Phone 805 895 2626 53 Aero Camino info fornoclassico com Goleta CA 93117 USA www fornocla...

Отзывы: