Factory Specified Manifold Pressures (W.C.) and associated BTU/hr. input values
for Forno Classico Commercial Series Ovens
Traditional Series
Installation and Operation Manual
An ongoing program of product improvement may require us to change
specifications without notice.
WS-TS Installation Manual,
Revised September 2016. Doc no: M0119.04
or visit
woodstone-corp.com
Wood Stone Corporation
1801 W. Bakerview Rd.
Bellingham, WA 98226 USA
Toll Free 800.988.8103
Tel 360.650.1111
Fax 360.650.1166
13
Hourly BTU/hr input rates for Wood Stone Traditional Series for models equipped to burn
Natural Gas (NG)
Hourly BTU/hr input rates for Wood Stone Traditional Series for models equipped to burn
Propane (LP)
Hourly BTU/hr input rates for Wood Stone Traditional Series for models equipped to burn
Hot Propane (HLP)
GAS SPECIFICATIONS
Wood Stone recommends that the appliance’s individual shutoff valve (supplied by others) be left readily accessible.
Wood Stone also recommends that inspection and maintenance of the burners and gas piping connections of this
appliance be performed at regularly scheduled intervals and only by professional gas appliance service agencies.
GAS CODE LIMITATIONS
The installation of this appliance must conform with local codes, or in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1 or The Natural Gas installation Code CAN/CGA-B149.1 as applicable, including:
The appliance and its individual shutoff valve (supplied by others) must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa).
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve (supplied by
others) during any pressure testing of the gas supply piping system at test pressure, equal to or less than 1/2 psi (3.45 kPa).
Burner Configuration
(NG)
RFG-IR-W, RFG-IR
RFG, RFG-W
W-IR
Model
WS-TS-5
188,000
105,000
83,000
WS-TS-6
188,000
105,000
83,000
Burner Configuration
(LP)
RFG-IR-W, RFG-IR
RFG, RFG-W
W-IR
Model
WS-TS-5
159,000
94,000
65,000
WS-TS-6
159,000
94,000
65,000
Burner Configuration
(HLP)
RFG-IR-W, RFG-IR
RFG, RFG-W
W-IR
Model
WS-TS-5
188,000
105,000
83,000
WS-TS-6
188,000
105,000
83,000
Colosso Oven
Model
W.C . (NG)
BTU/hr Input (NG)
W.C. (Propane)
BTU/hr
Imput
(
propane)
Colosso
65
5
’’
50.000
10
’’
65
Colosso
80
5
’’
55.000
10
’’
80
Colosso
100
5
’’
55.000
10
’’
100
Colosso
120
5
’’
55.000
10
’’
120
Colosso
140
5
’’
55.000
x
2
Burner
10
’’
140
Colosso
160
5
’’
55.000
x
2
Burner
10
’’
160
GAS SPECIFICATIONS CONT
Commerci
al Oven Series
Installation, Operation & Maintenance
Forno Classico
Forno Classico LLC
Phone: (805) 895
-
2626
5
3
Aero Camino [email protected]