![FORNI FEM107 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/forni/fem107/fem107_installation-operation-and-maintenance-instructions_2320380012.webp)
- 12 -
4.5.4 TRANSFORMATION FOR OPERATION WITH DIFFERENT ELECTRICAL
NETWORKS FOR DISTRIBUTION
Equipment is manufactured to operate with the following voltage values: 3N AC 380...415 V; 3 AC 220....240 V or AC 220....240
V 50 Hz. (in case of 60 Hz. power supply, request the appropriate kit).
If it is to be connected to one of these voltages, proceed as follows:
• Remove the right panel.
• Connect the power supply cable to the terminal block according to the mains voltage, following the wiring diagram and the
adhesive connection label placed near the terminal block.
Fasten the cable-clamp firmly after inserting a sufficient length of cable.
CONNECTIONS TO THE DIFFERENT ELECTRICAL NETWORKS
TYPE OF VOLTAGE
3N AC 380...415 V 50 Hz
3 AC 220...240 V 50 Hz
AC 220...240 V 50 Hz
WIRING DIAGRAM
DRAWING No.
15.2
24.5
41.3
I max.
A/f
No. cables
mm
2
MODEL
FEM67
FEM67SC
PE (Earth) yellow-green
N (NP) blue
L
3
(T) black
L
2
(S) black
L
1
(R) brown
3N AC 380...415 V
50 Hz
PE (Earth) yellow-green
L
3
(T) blue
L
2
(S) black
L
1
(R) brown
3 AC 220...240 V
50 Hz
PE (Earth) yellow-green
N (NP) blue
L
1
(R) brown
AC 220...240 V
50 Hz
5 x 1.5
4 x 2.5
3 x 10
FEM107
FEM107SC
11344
FEM207
FEM207SC
11346
12402
I max.
A/f
I max.
A/f
No. cables
mm
2
No. cables
mm
2
5 x 2.5
4 x 6
-
5 x 6
4 x 10
-
24.3
39.9
-
33.0
57.0
-