3
Different Coax/ Two Wire Cables Distance Chart for Reference:
Please note the cable quality, length and diameter of two wires used all have an
influence on the transfer of Data and the Power output.
Power Input DC 48V
CABLE
Distance
(Max)
Data Rate /
Mbps
DC 12V Output
Telephone cable
(0.65mm)
200-400M
72
500mA
UTP cable(CAT.5e)
600M
53
500mA
Coax Cable (RG59U)
300M
68
1A
1500M
11.2
X
Coax Cable(RG6U)
500M
73
1A
Power Input DC 56V
CABLE
Distance
(Max)
Data Rate /
Mbps
DC 12V Output
Telephone cable
(0.65mm)
200 ~ 400M
72
500mA
UTP cable(CAT.5e)
600M
55
1A
Coax Cable (RG59U)
500M
67
1A
1300M
9.5
x
Coax Cable(RG6U)
700M
72
1A
※
Recommend external power adapter must use DC 48
~
56V
.
LED Indication
:
LED Indication
Status
Function
Green
ON
Power ON/OFF
Blue
ON
Under Linking
Red
OFF
Linking failed
RJ45
(Green)
Green Flash Under Linking
Panel View:
FORESIGHT CCTV INC. | 5863 Leslie Street, Unit #713, Toronto, Ontario,Canada M2H1J8 | http://www.foresight-cctv.com | 1-888-GO2-CCTV