SETTING Button Function
:
One set of loop wiring with maximum 5 units of IP07M as below diagram:
When the installation over one set of loop wiring to switch, please make sure to
setting a group in order to avoid network conflict:
Use SETTING button to setup a group:
When two IP07M need to create a group, please follow the following steps:
1. Connect two IP07M first then press the SETTING button 5~8 seconds of first unit of IP07M,
the blue/green LED will be flashing.
2. Within 20 seconds, press SETTTING button 1~3 seconds of second unit of IP07M, the
second IP07M blue/green LED flashing.
3. After complete the above steps, the blue/green LED become ON status that mean the
group has successfully established
Reset to factory default:
To press the SETTING button 10 seconds, the blue/green LED will be flash. After reset the
green LED will be on.
Recommend to reset to factory default if you do not sure the unit have been set group or not.
If the unit already in group, press SETTING button 1~3 seconds will take no effect.
Group 1
Group 2
Group 3
Both wiring must be
away at least 30cm
Both wiring must be
away at least 30cm