![Fore Systems forerunner series Скачать руководство пользователя страница 230](http://html1.mh-extra.com/html/fore-systems/forerunner-series/forerunner-series_configuration-manual_2318854230.webp)
A - 10
ForeRunner
ATM Switch Network Configuration Manual
Configuring SNMP
121
asxDS3LOSCleared
This trap indicates that the incoming LOS Alarm has
been cleared on the specified DS3 port.
130
asxSonetLOFDetected
This trap indicates that the specified SONET port is
experiencing Loss Of Frame (LOF) failure. An LOF
failure is declared when the LOF defect persists for a
period of 2.5 +/- 0.5 seconds, except when an LOS
defect or failure is present.
131
asxSonetLOFCleared
This trap indicates that the LOF failure identified by
trap asxSonetLOFDetected has been cleared. The LOF
failure is cleared when the LOS failure is declared, or
when the LOF defect is absent for 10 +/- 0.5 seconds.
132
asxSonetLineRDIDetected
This trap indicates that the specified SONET port is
experiencing Line Remote Defect Indication (LRDI). A
Line RDI failure is declared when the incoming Line
RDI defects lasts for 2.5 +/- 0.5 seconds.
133
asxSonetLineRDICleared
This trap indicates that the Line RDI failure identified
by trap asxSonetLineRDIDetected has been cleared.
The Line RDI failure is cleared when no Line RDI
defects are detected for 10 +/- 0.5 seconds.
134
asxSonetPathAISDetected
This trap indicates that the specified SONET port is
experiencing Path Alarm Indication Signal (PAIS). A
Path AIS failure is declared when the Path AIS defect
persists for 2.5 +/- 0.5 seconds.
135
asxSonetPathAISCleared
This trap indicates that the Path AIS failure identified
by trap asxSonetPathAISDetected has been cleared. A
PAIS failure is cleared when the PAIS defect is absent
for 10 +/- 0.5 seconds.
136
asxSonetPathLOPDetected
This trap indicates that the specified SONET port is
experiencing Loss Of Pointer (LOP). A LOP failure is
declared when the LOP defect persists for a period of
2.5 +/- 0.5 seconds.
137
asxSonetPathLOPCleared
This trap indicates that the LOP failure identified by
trap asxSonetLOPDetected has been cleared. A LOP
failure is cleared when the LOP defect is absent for 10
+/- 0.5 seconds.
Table A.2 -
SNMP Traps Supported on the ForeRunner Switches (Continued)
Trap
Number
Trap Name
Description
Содержание forerunner series
Страница 6: ......
Страница 16: ...TOC 10 ForeRunner ATM Switch Network Configuration Manual Table of Contents ...
Страница 20: ...LOF 4 ForeRunner ATM Switch Network Configuration Manual List of Figures ...
Страница 22: ...LOT 2 ForeRunner ATM Switch Network Configuration Manual List of Tables ...
Страница 30: ...viii ForeRunner ATM Switch Network Configuration Manual Preface ...
Страница 144: ...3 58 ForeRunner ATM Switch Network Configuration Manual Configuring an Emulated LAN ...
Страница 180: ...6 12 ForeRunner ATM Switch Network Configuration Manual ATM Forum PNNI ...
Страница 220: ...9 6 ForeRunner ATM Switch Network Configuration Manual Configuring Timing ...
Страница 300: ...D 24 ForeRunner ATM Switch Network Configuration Manual Configuring FramePlus Modules ...
Страница 308: ...Acronyms 8 ForeRunner ATM Switch Network Configuration Manual Acronyms ...
Страница 346: ...Glossary 38 ForeRunner ATM Switch Network Configuration Manual Glossary ...
Страница 352: ...Index 6 ForeRunner ATM Switch Network Configuration Manual Index ...