SKML9J-10C823-BA

WARNING

- Immediately notify Customer Service if the charge sta-
tion, charging cable or the charging coupling are dam-
aged. Do not continue to use the charge station.
- Prevent the charging cable and coupling from coming
into contact with external heat sources, water, dirt, and
chemicals.
- Switch off power at the circuit breaker before installing
or cleaning.
- Do not attach extension cables or adapters to the
charging cable.
- Never clean the charge station with a high-pressure
cleaner or similar.
- Switch off the power supply before cleaning the charg-
ing sockets.
- The charging cable must not be subjected to any strain
during use.
- You must make sure that no one has access to the
charge station without reading this user manual first.
- Make sure that the charge station temperature is within
its storage temperature limits when moving, transport-
ing, or storing it.
- You are strictly prohibited from pulling the charge sta-
tion by its cable.

WARNING

When transporting the Ford Connected Charge Station ,
handle with care. Do not subject it to strong force or im-
pact, also do not pull, twist, tangle, drag, or step on the
Ford Connected Charge Station to prevent damaging it
or any of its components.

NOTICE

In addition to the safety instructions in this document,
also observe further safety instructions in any other en-
closed documents.

2.3

Safety information for installation

WARNING

- Only use the supplied or other appropriate installation
material.
- When the charge station is open, ESD (electrostatic dis-
charge) precautions must be taken properly to avoid
electrostatic discharge.
- When handling electrostatically sensitive boards, wear
grounded antistatic wrist straps and properly observe
ESD safety precautions. (To be used only for mounting
and connecting the loading unit. The wrist strap must
not be worn under a live charge station.)
- Electricians must be properly grounded during installa-
tion of the charge station.
- Do not install the charge station in an explosion sensi-
tive area (EX zone).
- Install the charge station in such a way that the charg-
ing cable does not block any passageways.
- Do not install the charge station in areas subject to am-
monia, or air containing ammonia.
- Do not install the charge station in a location where
falling objects may damage it.
- The charge station is suitable for indoor and outdoor
use.
- Do not install the charge station in the vicinity of water
jets, such as car wash installations, high-pressure clean-
ers, or garden hoses.
- Protect the charge station against damage caused by
sub-zero temperatures, hail, and similar.
- The charge station is suitable for use in areas without
access restrictions.
- Protect the charge station from direct sunlight. The
charging current may be reduced at high temperatures,
or charging may be disabled completely. The operating
temperature range is -40°F to +140°F (-40 °C to
+60°C).
- The installation location of the charge station should
be such that vehicles cannot inadvertently collide with it.
Protective measures must be implemented if the possi-
bility of damage cannot be ruled out.

WARNING

- Do not put the charge station into operation if it has
been damaged during installation. A replacement will be
required instead.
- Do not touch the electronics during the installation
process.

2.4

Safety information for electrical
connection

WARNING

- You must protect each charge station with its own line
circuit breaker and residual current circuit breaker.
- A qualified electrician must make sure that all electrical
connections are de-energized before connecting the
charge station to the power supply.
- A qualified electrician must make sure that a properly
sized supply cable is used for the power connection.
- Do not leave the charge station unattended with the
cover open.
- Register the installation of your charge station with
your power supply company if this is required by law or
by any agreement.

2.5

Safety information for initial start up

WARNING

- The initial startup of the charge station must be carried
out by a qualified electrician.
- Before initial start-up, the qualified electrician must
verify that the charge station has been connected cor-
rectly.
- Do not connect a vehicle to the charge station during its
initial startup.
- Before starting up the charge station, inspect the
charging cable, charging coupler, and the charge station
for visible damage. The device must not be started up if
it has been damaged, or if the charging cable / charging
coupler has been damaged.

Содержание Connected Charge Station

Страница 1: ...Installation manual 48A Single Phase Ford Connected Charge Station ...

Страница 2: ...GND X2 X1 1 L2 L1 GND 2 3 4 5 1 6 ...

Страница 3: ...7 8 9 10 11 12 ...

Страница 4: ...13 14 15 16 17 18 ...

Страница 5: ...A B C D E F G H AA AB AC AD AE AF AG 0 5 x 3 5 mm 29 mm 36 mm 40 mm T x 6 T x 20 T x 25 3 mm 1 8 Inch 8 mm 3 8 Inch 19 ...

Страница 6: ...DIP switch settings 4 5 2 2 Power supply isolation device 4 5 2 3 Dimensioning the lead s cross section 4 5 3 Step by step installation 5 5 3 1 Required tools 5 5 3 2 Installing the mounting bracket 5 5 3 3 Removing the front cover 5 5 3 4 Installing the blind plugs and conduit fitting 5 5 3 5 Installing the charging cable 6 5 3 6 Mounting the rear housing 6 5 3 7 Connecting the grid cable 6 5 3 8...

Страница 7: ... Station has been developed produced tested and documented according to the rele vant safety regulations and environmental requirements that apply to your geographical area You must only use the charge station in a technically fault less condition Any malfunctions that adversely affect the safety of persons or of the device must be immediately rec tified by a qualified electrician in accordance wi...

Страница 8: ...ageways Do not install the charge station in areas subject to am monia or air containing ammonia Do not install the charge station in a location where falling objects may damage it The charge station is suitable for indoor and outdoor use Do not install the charge station in the vicinity of water jets such as car wash installations high pressure clean ers or garden hoses Protect the charge station...

Страница 9: ... kg Installation height Minimally 35 inches above floor level regarding to the bottom of the de vice Minimally 900 mm above floor level regarding to the bottom of the de vice IP protection class NEMA Type 3S IP65 Protection against mechanical impact UL2994 Ambient conditions Operating tempera ture range 40 F to 140 F 40 C to 60 C Storage tempera ture range C 40 F to 185 F 40 C to 85 C Altitude m M...

Страница 10: ...ct sunlight and spray to extend its useful life and fault free operation 5 2 Criteria for electrical connection The Ford Connected Charge Station type label indicates the maximum charging current that you can configure The type label on the Ford Connected Charge Station is located on the right The power availability at the service connection determines the maximum permitted charging current A qual...

Страница 11: ...rx T25 screwdriver and two screws 6 x 90 mm x 3 inch to mount the bracket on the pole 5 3 3 Removing the front cover Use a Torx T25 screwdriver to remove the three transport safety screws M4 x 16 mm inch from the front cover as shown in Fig 4 and make sure to keep these for later in stallation Fig 4 5 3 4 Installing the blind plugs and conduit fitting 1 Choose the appropriate conduit in accordance...

Страница 12: ...grip The upper part has larger screw holes and recesses in which the screws can move freely 5 3 6 Mounting the rear housing Use a Torx T20 screwdriver and two screws M4 x 16 mm to mount the rear housing onto the mount bracket torque 4Nm 3 ft lb Fig 10 5 3 7 Connecting the grid cable To connect the grid cable to the Ford Connected Charge Sta tion 1 Remove any debris such as insulation trimmings fro...

Страница 13: ...older out of the box 2 Mark the drill holes by using the rear part of the dock holder as a template 3 Drill two holes 8 mm 5 16 inch in the marked posi tions 4 Push the two dowels 8 x 50 mm 5 16 x 2 Inches firmly into the drill holes 5 Use a Torx T20 screwdriver and two screws 6 x 90 mm x 3 5 inches to mount the dock s rear holder on the wall Fig 16 6 Carefully clip the dock front cover onto dock ...

Страница 14: ...tibility To download the User Manual Installation Manual for the Ford Connected Charge Station browse to https owner ford com or www ford ca owners Published October 20 2020 5110776 CL1 WALLBOX FORD INSTALLATION MANUAL SAE 10 Installation checklist Please complete the Ford Connected Charge Station instal lation checklist Variant 1 phase Serial number Material number General preconditions Installat...