Ford Connected Charge Station Скачать руководство пользователя страница 14

EN-

US

8

Ford Connected Charge Station Installation manual

SKML9J-10C823-BA

The following steps apply:
1.

Switch off the charge station circuit breaker.

2. Electrically disconnect the charge station.
3. Dispose of the Ford Connected Charge Station in accor-

dance with local and national rules and regulations.

8

Maintenance, cleaning, and repair

8.1

Maintenance

Maintenance should only be carried out by a qualified elec-
trician and must be in accordance with local regulations,
standards, and requirements.

8.2

Cleaning

DANGER

High voltages.

Danger of fatal electric shock. Never clean the charge
station with a high-pressure cleaner or similar device.

u

Only clean the Ford Connected Charge Station with a dry
cloth. Never use aggressive cleaning agents, solvents,
fuel, or wax.

8.3

Repair

Unauthorized repair of the Ford Connected Charge Station is

 

not permitted. In case of failure, the entire unit must be re-
placed. Ford Motor Company Limited (Ford) reserves the ex-
clusive right to perform repairs to the charge station . The

 

only serviceable components are the design cover and the

 

charging cable. The charging cable must be 

replaced

 by a

 

qualified electrician.

NOTICE

You can replace the charging cable a maximum of four
times over the lifetime of the charge station.

9

Declaration of Conformity

Ford Motor Company Limited (Ford) hereby declares that
the radio equipment type "Ford Connected Charge Station"
conforms to UL2594 and to CAN/CSA-C22.2 No. 280-16, No
281.1-12 and No. 281.2-12 applied for general use of power
supplies.
The Ford Connected Charge Station also conforms to the
following standards and regulations:

– UL2594

– FCC Part 15, Subpart B and C UL2231-1,2
– NEC Article 625 compliant

The Ford Connected Charge Station was developed, manu-
factured, tested, and supplied in accordance with the
above-mentioned standards and regulations, and in accor-
dance with the relevant standards for safety, electromag-
netic compatibility (EMC), and environmental compatibility.
To download the User Manual / Installation Manual for the
Ford Connected Charge Station, browse to

https://

owner.ford.com/

 or 

www.ford.ca/owners

********************
Published October 20, 2020
5110776 CL1: WALLBOX FORD INSTALLATION MANUAL SAE

10

Installation checklist

Please complete the Ford Connected Charge Station instal-
lation checklist

Variant:

1-phase

Serial number:

Material number:

General preconditions:

Installation, electrical connection, and initial opera-
tion of the charge station has been carried out by a
qualified electrician.

The charge station has been inspected for visual
damage before installation and use.

Local installation conditions:

The charge station has not been installed in an ex-
plosion sensitive area (Ex Zone).

To achieve optimal performance of the charge sta-
tion, areas with direct sunlight have been avoided.

The charge station has been installed in a location
where falling objects cannot damage the charge sta-
tion.

The location of the charge station has been selected
in such a way that vehicles cannot inadvertently col-
lide with it.

The legal requirements for electrical installations,
fire protection, safety regulations, and escape routes
have been met.

The use of the correct residual current circuit breaker
(RDB) and the correct residual current device (RCD)
have been ensured.

The charging cable does not obstruct any passage-
ways.

The charging cable and coupling has been protected
against coming into contact with external heat
sources, water, dirt, and chemicals.

The charging cable and coupling has been protected
against being driven over, trapped, or any other me-
chanical hazards.

Charging station installation requirements:

Tools and installation materials have been removed
from the charge station before closing the cover.

A suitable charging cable has been installed in the
charge station (as per the type label) during installa-
tion.

The charging cable has been connected as per instal-
lation instructions.

The customer has been instructed on how to use the
charge station correctly.

The installer has checked correct operation of the
charge station using an EV-simulator / tester.

Customer/client:

Date:

Electrician/contractor:

Date:

Содержание Connected Charge Station

Страница 1: ...Installation manual 48A Single Phase Ford Connected Charge Station ...

Страница 2: ...GND X2 X1 1 L2 L1 GND 2 3 4 5 1 6 ...

Страница 3: ...7 8 9 10 11 12 ...

Страница 4: ...13 14 15 16 17 18 ...

Страница 5: ...A B C D E F G H AA AB AC AD AE AF AG 0 5 x 3 5 mm 29 mm 36 mm 40 mm T x 6 T x 20 T x 25 3 mm 1 8 Inch 8 mm 3 8 Inch 19 ...

Страница 6: ...DIP switch settings 4 5 2 2 Power supply isolation device 4 5 2 3 Dimensioning the lead s cross section 4 5 3 Step by step installation 5 5 3 1 Required tools 5 5 3 2 Installing the mounting bracket 5 5 3 3 Removing the front cover 5 5 3 4 Installing the blind plugs and conduit fitting 5 5 3 5 Installing the charging cable 6 5 3 6 Mounting the rear housing 6 5 3 7 Connecting the grid cable 6 5 3 8...

Страница 7: ... Station has been developed produced tested and documented according to the rele vant safety regulations and environmental requirements that apply to your geographical area You must only use the charge station in a technically fault less condition Any malfunctions that adversely affect the safety of persons or of the device must be immediately rec tified by a qualified electrician in accordance wi...

Страница 8: ...ageways Do not install the charge station in areas subject to am monia or air containing ammonia Do not install the charge station in a location where falling objects may damage it The charge station is suitable for indoor and outdoor use Do not install the charge station in the vicinity of water jets such as car wash installations high pressure clean ers or garden hoses Protect the charge station...

Страница 9: ... kg Installation height Minimally 35 inches above floor level regarding to the bottom of the de vice Minimally 900 mm above floor level regarding to the bottom of the de vice IP protection class NEMA Type 3S IP65 Protection against mechanical impact UL2994 Ambient conditions Operating tempera ture range 40 F to 140 F 40 C to 60 C Storage tempera ture range C 40 F to 185 F 40 C to 85 C Altitude m M...

Страница 10: ...ct sunlight and spray to extend its useful life and fault free operation 5 2 Criteria for electrical connection The Ford Connected Charge Station type label indicates the maximum charging current that you can configure The type label on the Ford Connected Charge Station is located on the right The power availability at the service connection determines the maximum permitted charging current A qual...

Страница 11: ...rx T25 screwdriver and two screws 6 x 90 mm x 3 inch to mount the bracket on the pole 5 3 3 Removing the front cover Use a Torx T25 screwdriver to remove the three transport safety screws M4 x 16 mm inch from the front cover as shown in Fig 4 and make sure to keep these for later in stallation Fig 4 5 3 4 Installing the blind plugs and conduit fitting 1 Choose the appropriate conduit in accordance...

Страница 12: ...grip The upper part has larger screw holes and recesses in which the screws can move freely 5 3 6 Mounting the rear housing Use a Torx T20 screwdriver and two screws M4 x 16 mm to mount the rear housing onto the mount bracket torque 4Nm 3 ft lb Fig 10 5 3 7 Connecting the grid cable To connect the grid cable to the Ford Connected Charge Sta tion 1 Remove any debris such as insulation trimmings fro...

Страница 13: ...older out of the box 2 Mark the drill holes by using the rear part of the dock holder as a template 3 Drill two holes 8 mm 5 16 inch in the marked posi tions 4 Push the two dowels 8 x 50 mm 5 16 x 2 Inches firmly into the drill holes 5 Use a Torx T20 screwdriver and two screws 6 x 90 mm x 3 5 inches to mount the dock s rear holder on the wall Fig 16 6 Carefully clip the dock front cover onto dock ...

Страница 14: ...tibility To download the User Manual Installation Manual for the Ford Connected Charge Station browse to https owner ford com or www ford ca owners Published October 20 2020 5110776 CL1 WALLBOX FORD INSTALLATION MANUAL SAE 10 Installation checklist Please complete the Ford Connected Charge Station instal lation checklist Variant 1 phase Serial number Material number General preconditions Installat...