![Ford Connected Charge Station Скачать руководство пользователя страница 14](http://html1.mh-extra.com/html/ford/connected-charge-station/connected-charge-station_installation-manual_2318648014.webp)
EN-
US
8
Ford Connected Charge Station Installation manual
SKML9J-10C823-BA
The following steps apply:
1.
Switch off the charge station circuit breaker.
2. Electrically disconnect the charge station.
3. Dispose of the Ford Connected Charge Station in accor-
dance with local and national rules and regulations.
8
Maintenance, cleaning, and repair
8.1
Maintenance
Maintenance should only be carried out by a qualified elec-
trician and must be in accordance with local regulations,
standards, and requirements.
8.2
Cleaning
DANGER
High voltages.
Danger of fatal electric shock. Never clean the charge
station with a high-pressure cleaner or similar device.
u
Only clean the Ford Connected Charge Station with a dry
cloth. Never use aggressive cleaning agents, solvents,
fuel, or wax.
8.3
Repair
Unauthorized repair of the Ford Connected Charge Station is
not permitted. In case of failure, the entire unit must be re-
placed. Ford Motor Company Limited (Ford) reserves the ex-
clusive right to perform repairs to the charge station . The
only serviceable components are the design cover and the
charging cable. The charging cable must be
replaced
by a
qualified electrician.
NOTICE
You can replace the charging cable a maximum of four
times over the lifetime of the charge station.
9
Declaration of Conformity
Ford Motor Company Limited (Ford) hereby declares that
the radio equipment type "Ford Connected Charge Station"
conforms to UL2594 and to CAN/CSA-C22.2 No. 280-16, No
281.1-12 and No. 281.2-12 applied for general use of power
supplies.
The Ford Connected Charge Station also conforms to the
following standards and regulations:
– UL2594
– FCC Part 15, Subpart B and C UL2231-1,2
– NEC Article 625 compliant
The Ford Connected Charge Station was developed, manu-
factured, tested, and supplied in accordance with the
above-mentioned standards and regulations, and in accor-
dance with the relevant standards for safety, electromag-
netic compatibility (EMC), and environmental compatibility.
To download the User Manual / Installation Manual for the
Ford Connected Charge Station, browse to
or
********************
Published October 20, 2020
5110776 CL1: WALLBOX FORD INSTALLATION MANUAL SAE
10
Installation checklist
Please complete the Ford Connected Charge Station instal-
lation checklist
Variant:
1-phase
Serial number:
Material number:
General preconditions:
√
Installation, electrical connection, and initial opera-
tion of the charge station has been carried out by a
qualified electrician.
The charge station has been inspected for visual
damage before installation and use.
Local installation conditions:
The charge station has not been installed in an ex-
plosion sensitive area (Ex Zone).
To achieve optimal performance of the charge sta-
tion, areas with direct sunlight have been avoided.
The charge station has been installed in a location
where falling objects cannot damage the charge sta-
tion.
The location of the charge station has been selected
in such a way that vehicles cannot inadvertently col-
lide with it.
The legal requirements for electrical installations,
fire protection, safety regulations, and escape routes
have been met.
The use of the correct residual current circuit breaker
(RDB) and the correct residual current device (RCD)
have been ensured.
The charging cable does not obstruct any passage-
ways.
The charging cable and coupling has been protected
against coming into contact with external heat
sources, water, dirt, and chemicals.
The charging cable and coupling has been protected
against being driven over, trapped, or any other me-
chanical hazards.
Charging station installation requirements:
Tools and installation materials have been removed
from the charge station before closing the cover.
A suitable charging cable has been installed in the
charge station (as per the type label) during installa-
tion.
The charging cable has been connected as per instal-
lation instructions.
The customer has been instructed on how to use the
charge station correctly.
The installer has checked correct operation of the
charge station using an EV-simulator / tester.
Customer/client:
Date:
Electrician/contractor:
Date:
Содержание Connected Charge Station
Страница 1: ...Installation manual 48A Single Phase Ford Connected Charge Station ...
Страница 2: ...GND X2 X1 1 L2 L1 GND 2 3 4 5 1 6 ...
Страница 3: ...7 8 9 10 11 12 ...
Страница 4: ...13 14 15 16 17 18 ...