READ BEFORE YOU INSTALL YOUR ELECTRIC FENCE ENERGISER    Page 1

 Only use this electric fence energiser for the purpose

    indicated in this manual. 

 RISK OF ELECTRIC SHOCK!  To reduce the risk of

    electric shock do not open the energiser.  Refer to
    trained service personnel or service centre.

 Always turn off energiser before handling.

 Never modify the design of an energiser.

● Avoid contacting electric fence wires especially with
    the head, neck or torso.
● Do not climb over, through or under a multi-wire
    electric fence. Use a gate or a specially designed
    crossing point.

 The appliance is not to be used by persons (including

    children of 8 years old and below) with reduced
    physical, sensory or mental capabilities, or lack of
    experience and knowledge, unless they have been
    given supervision or instruction in the use of the
    appliance in a safe way and understand the hazards
    involved.
● Children shall not play with the appliance.
● Cleaning and user maintenance shall not be made by
    children without supervision.
● DO NOT install where children, elderly or unhealthy
    persons may come in contact with the live portions of
    electric fencing. Use electric fence warning signs
    where humans may come in contact with the fence.

WARNINGS

READ ALL INSTRUCTIONS BEFORE

INSTALLATION AND USE.

Содержание DUALGIZER DG1

Страница 1: ...Installation Operation Instructions SAVE THESE INSTRUCTIONS AC DC Dual Power Electric Fence Energiser AC DC MODE DISPLAY Adapter or Battery Input OUTPUT DISPLAY NAVI BUTTON MOUNTING HOLES...

Страница 2: ...Blank page...

Страница 3: ...ally designed crossing point The appliance is not to be used by persons including children of 8 years old and below with reduced physical sensory or mental capabilities or lack of experience and knowl...

Страница 4: ...mbol of Figure 1 or the substance of the wording CAUTION Electric fence The inscription shall be indelible inscribed on both sides of the warning sign and have a height of at least 25 mm Barbed wire o...

Страница 5: ...that are run underground shall be run in conduit of insulating material or else insulated high voltage cable shall be used Care must be taken to avoid damage to the connecting leads due to the effect...

Страница 6: ...tive psychological barriers when properly installed and when animals are trained to the fence Electric fences are NOT complete physical barriers Erratic animal behavior cannot be predicted and occasio...

Страница 7: ...nks 5 Training Finally it is very important that an animal s first experience with an electric fence shock is one of respect Some animals require more than one shock experience for lasting respect of...

Страница 8: ...ack fence terminal knob on the right and remove it together with the top washer 2 Make a J shape in a bare end of hook up wire unless the wire is too stiff then use it straight 3 Hook this bare end of...

Страница 9: ...he circuit needed for delivering an effective shock 1 Locate an area of soil for ground rods that contains good conductive earth not sandy or rocky Soil that is moist throughout the year is best The g...

Страница 10: ...s too stiff then use it straight 3 Hook this bare end of wire over the terminal bolt or lay the straight wire up into the top recess 4 Replace the top washer and the red knob and hand tighten 10 to 14...

Страница 11: ...ENERGISER INSTALLATION continued Page 9 Step 4 continued Properly connect the hook up wire from the energiser to the fence line s using appropriate connection methods to ensure a good connection Joint...

Страница 12: ...nd socket it is recommended to use the incorporated Plug Lock This is the part attached below the DC socket With the Plug Lock to the right insert the DC plug into the socket Slide the Plug Lock to th...

Страница 13: ...pulse onto the fence The unit is in Full Power Mode so the larger lightening bolt mode LED is lit Press the Navi Button again and the unit will switch to Half Power Mode and the smaller lightening bol...

Страница 14: ...is to walk the fence and listen for arcs if you don You should not hear this snapping sound at the fence connections The sound is similar to a static electricity spark when touching a door knob after...

Страница 15: ...en selecting a lead acid or marine type rechargeable battery to know how many days this battery will run your energiser until you have to replace recharge These are approximate and are only valid for...

Страница 16: ...lised Separate Power Supply 100 240VAC Input 12V DC 1 5A Output Fence Energiser Complies with EN 60335 1 60335 2 76 AS NZS 60335 1 60335 2 76 EN 61000 3 2 EN 61000 3 3 EN 61000 6 2 EN 61000 6 4 AS NZS...

Отзывы: