![Forcefield DUALGIZER DG1 Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/forcefield/dualgizer-dg1/dualgizer-dg1_installation-and-operation-instructions_2317140013.webp)
ENERGISER TEST (Steps 7-8) Page 11
Note:
Full-Power is the normal operating mode.
Half-Power mode is mainly used for animals
that are trained to an electric fence or if you
want to extend the number of days before
swapping batteries, or if you are not
concerned about predator animals.
Full
Power
Half
Power
OFF
Navi-Button Sequence
2
1
3
PULSE
Full
Half
LOW OUTPUT
WARNING
Separate
Power Supply
or
12V Battery
Step 7: Test Energiser
●
With the energiser off, press and release the “Navi-Button” once.
The unit will start in
Full-Power Mode
, putting a high voltage pulse onto the fence.
The unit is in
Full-Power Mode
so the larger lightening bolt ( ) mode LED is lit.
●
Press the “Navi-Button” again and the unit will switch to
Half-Power Mode
and the
smaller lightening bolt ( ) mode LED is lit.
●
For each pulse, the vertical row of green LEDs will light up to show the output kV
to the fence. The more that light, the higher the output kV.
●
While in Half-Power mode press and release the “Navi-Button” another time and
the unit will turn off.
●
So, the unit cycles from OFF --› FULL POWER --› HALF POWER --› OFF as you
press the “Navi-Button”.
Not
e:
If the energiser’s power is disconnected while
it is on, when the power is re-connected, it will
continue in the last mode it was in before
disconnection.
Only use supplied
12VDC approved
Separate Supply Unit
Содержание DUALGIZER DG1
Страница 2: ...Blank page...