ENERGISER INSTALLATION continued. Page 8
Step 3: Connect the fence live (hot) terminal
“J” shape
or straight
CAUTION
DO NOT use pliers or other mechanical
means to tighten the terminal knobs
or they may be over-tightened and damaged.
Red
Note:
Ensure the energiser is OFF before making this connection or you may receive
a shock.
1. Unscrew the red fence terminal knob ( ) and remove it together with the top
washer.
2. Make a “J” shape in a bare end of hook-up wire, unless the wire is too stiff, then
use it straight.
3. Hook this bare end of wire over the terminal bolt or lay the straight wire up into the
top recess.
4. Replace the top washer and the red knob and hand tighten.
10 to 14 gauge insulated lead-out wire
(rated 20,000V) is commonly used for this.
5. Properly connect the other end of the wire
to your fence. See step 4.
Refer to Diagram 2 on following page:
WIRE SPLICING AND CONNECTIONS.
Connect the Black terminal
( ) to the Ground rod
using the Black lead.
Connect the Red terminal
( ) to the Fence line using
the Red lead.
Ground rod
Live Fence Wire
Live Fence Wire
Live Fence Wire
Step 4: Connect to the fence
Mark the top
of the ground
rod as a hazard