Fora TD-3261G Скачать руководство пользователя страница 68

Federal

 

Communications

 

Commission

 

(FCC)

 

Statement

 

15.21

 

You

 

are

 

cautioned

 

that

 

changes

 

or

 

modifications

 

not

 

expressly

 

approved

 

by

 

the

 

part

 

responsible

 

for

 

compliance

 

could

 

void

 

the

 

user’s

 

authority

 

to

 

operate

 

the

 

equipment.

 

 

15.105(b)

 

This

 

equipment

 

has

 

been

 

tested

 

and

 

found

 

to

 

comply

 

with

 

the

 

limits

 

for

 

a

 

Class

 

B

 

digital

 

device,

 

pursuant

 

to

 

part

 

15

 

of

 

the

 

FCC

 

rules.

 

These

 

limits

 

are

 

designed

 

to

 

provide

 

reasonable

 

protection

 

against

 

harmful

 

interference

 

in

 

a

 

residential

 

installation.

 

This

 

equipment

 

generates,

 

uses

 

and

 

can

 

radiate

 

radio

 

frequency

 

energy

 

and,

 

if

 

not

 

installed

 

and

 

used

 

in

 

accordance

 

with

 

the

 

instructions,

 

may

 

cause

 

harmful

 

interference

 

to

 

radio

 

communications.

 

However,

 

there

 

is

 

no

 

guarantee

 

that

 

interference

 

will

 

not

 

occur

 

in

 

a

 

particular

 

installation.

 

If

 

this

 

equipment

 

does

 

cause

 

harmful

 

interference

 

to

 

radio

 

or

 

television

 

reception,

 

which

 

can

 

be

 

determined

 

by

 

turning

 

the

 

equipment

 

off

 

and

 

on,

 

the

 

user

 

is

 

encouraged

 

to

 

try

 

to

 

correct

 

the

 

interference

 

by

 

one

 

or

 

more

 

of

 

the

 

following

 

measures:

 

 

Reorient

 

or

 

relocate

 

the

 

receiving

 

antenna.

 

Increase

 

the

 

separation

 

between

 

the

 

equipment

 

and

 

receiver.

 

Connect

 

the

 

equipment

 

into

 

an

 

outlet

 

on

 

a

 

circuit

 

different

 

from

 

that

 

to

 

which

 

the

 

receiver

 

is

 

connected.

 

Consult

 

the

 

dealer

 

or

 

an

 

experienced

 

radio/TV

 

technician

 

for

 

help.

 

 

This

 

device

 

complies

 

with

 

Part

 

15

 

of

 

the

 

FCC

 

Rules.

   

Operation

 

is

 

subject

 

to

 

the

 

following

 

two

 

conditions:

 

1)

 

this

 

device

 

may

 

not

 

cause

 

harmful

 

interference

 

and

 

2)

 

this

 

device

 

must

 

accept

 

any

 

interference

 

received,

 

including

 

interference

 

that

 

may

 

cause

 

undesired

 

operation

 

of

 

the

 

device.

 

 

Innovation,

 

Science

 

and

 

Economic

 

Development

 

Canada

 

(ISED)

 

statement

 

This

 

Class

 

B

 

digital

 

apparatus

 

complies

 

with

 

Canadian

 

ICES

003

 

and

 

RSS

247.

 

This

 

device

 

contains

 

licence

exempt

 

transmitter(s)/receiver(s)

 

that

 

comply

 

with

 

Innovation,

 

Science

 

and

 

Economic

 

Development

 

Canada’s

 

licence

exempt

 

RSS(s).

   

Operation

 

is

 

subject

 

to

 

the

 

following

 

two

 

conditions:

 

(1)this

 

device

 

may

 

not

 

cause

 

interference,

 

and

   

(2)this

 

device

 

must

 

accept

 

any

 

interference,

 

including

 

interference

 

that

 

may

 

cause

 

undesired

 

operation

 

of

 

the

 

device.

 

 

Cet

 

appareil

 

numérique

 

de

 

classe

 

B

 

est

 

conforme

 

à

 

la

 

norme

 

NMB

003

 

et

 

RSS

247

 

L’émetteur/récepteur

 

exempt

 

de

 

licence

 

contenu

 

dans

 

le

 

présent

 

appareil

 

est

 

conforme

 

aux

 

CNR

 

d’Innovation,

 

Sciences

 

et

 

Développement

 

économique

 

Canada

 

applicables

 

aux

 

appareils

 

radio

 

exempts

 

de

 

licence.

 

L’exploitation

 

est

 

autorisée

 

aux

 

deux

 

conditions

 

suivantes

 

:

 

(1)

 

l'appareil

 

ne

 

doit

 

pas

 

produire

 

de

 

brouillage,

 

et,

 

and

 

(2)

 

l'utilisateur

 

de

 

l'appareil

 

doit

 

accepter

 

tout

 

brouillage

 

radioelectrique

 

subi,

 

meme

 

si

 

le

 

brouillage

 

est

 

susceptible

 

d'en

 

compromettre

 

le

 

fonctionnement.

 

 

 

Содержание TD-3261G

Страница 1: ...Owner s Manual FORA TD 3261G Blood Glucose Plus Blood Pressure Monitoring System...

Страница 2: ...2...

Страница 3: ...also suggest that diabetes patients could reduce the risk of cardiovascular diseases by managing their blood glucose levels and blood pressure Therefore with easy operation of this TD 3261G Blood Gluc...

Страница 4: ...s a cure for any symptoms or diseases The data measured is for reference only Always consult your physician to have the results interpreted 6 Before using this device to test blood glucose read all in...

Страница 5: ...and periodically control solution test are essential to the longevity of your device If you are concerned about your accuracy of measurement please contact local customer service for help 13 Always c...

Страница 6: ...Display 12 Test Strip 13 Features 14 SETTING THE MONITOR 15 TESTING YOUR BLOOD GLUCOSE 19 The Four Measuring Modes 19 QUALITY CONTROL TESTING 21 Performing a Control Solution Test 21 TESTING WITH BLO...

Страница 7: ...verage Results 38 DATA TRANSMISSION VIA BLUETOOTH 40 DATA TRANSMISSION VIA 4G 42 MAINTENANCE 45 Battery 45 Using AC Adapter 46 Caring for Your Monitor 47 Caring for Your Test Strips 48 Important Contr...

Страница 8: ...toms or continue to get results higher or lower than usual follow the treatment advice of your healthcare professional Use only fresh whole blood sample to test your blood glucose Using other substanc...

Страница 9: ...es and hypertension This system has voice function but is not designed for the visually impaired Test Principle Your system measures the amount of sugar glucose in whole blood The glucose testing is b...

Страница 10: ...10 Monitor Overview Front Side Back Pressure Cuff 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18...

Страница 11: ...measurement AVERAGE BUTTON Assists you with blood pressure average mode Speaker RF INDICATOR Indicates a wireless data transmission 1 3 4 2 6 11 10 15 12 16 13 17 14 8 9 5 7 POWER INDICATOR Indicates...

Страница 12: ...l Face Low High Symbol Ketone Warning Heart Symbol for IHB Detection Irregular Heart Beat Pulse Rate Day Average Result Indicator Low Battery Symbol Memory Symbol Unit for Blood Pressure Unit for Bloo...

Страница 13: ...wrong if the contact bar is not fully inserted into the test slot Front Absorbent Hole Apply a drop of blood here The blood will be automatically absorbed Confirmation Window This is where you confir...

Страница 14: ...res Model Data Transmission Function For TD 3261G Test results can be viewed through a wireless connection by using 4G For TD 3261B Test results can be viewed through a wireless connection by using Bl...

Страница 15: ...he steps below and have your desired settings saved Entering the setting mode Start with the monitor off no test strip inserted Press until the monitor turns on Step 1 Setting the date With the year f...

Страница 16: ...ars Press Step 2 Setting the time With the hour flashing press until the correct hour appears Press With the minute flashing press until the correct minute appears Press Step 3 Setting the time format...

Страница 17: ...referring to the 4G or Bluetooth service If On is selected your result will be transmitted right after the test Step 6 Setting the auto send Press to select the auto send On or OFF Press Step 5 Settin...

Страница 18: ...sults press twice Step 8 Setting the cycle mode Press to choose the desired blood pressure cycle mode from the following time interval selections OFF 5 10 15 20 30 40 or 60 minutes Press to turn off t...

Страница 19: ...or at least 8 hours 2 hours after a meal testing with the control solution You can switch between each mode by Step 1 Start with the monitor switched off Insert a test strip to turn on the monitor The...

Страница 20: ...20 Step 2 Press to switch between General AC PC and QC mode...

Страница 21: ...ot accurate to practice testing process or if you have dropped or think you may have damaged the monitor Performing a Control Solution Test Step 1 Insert the test strip to turn on the monitor Insert t...

Страница 22: ...esults in memory Step 3 Apply Control Solution Shake the control solution vial thoroughly before use Squeeze out a drop and wipe it off then squeeze another drop and place it on the tip of the vial ca...

Страница 23: ...t 109 165 Normal Out of range results If you continue to have test results fall outside the range printed on the test strip vial the monitor and strips may not be working properly Do NOT test your blo...

Страница 24: ...e Stimulating blood perfusion by rubbing the puncture site prior to blood extraction has a significant influence on the glucose value obtained Blood from a site that has not been rubbed exhibits a mea...

Страница 25: ...begin AST It is recommended to discard the first drop of blood as it might contain tissue fluid which may affect the test result Fingertip testing Press the lancing device s tip firmly against the lo...

Страница 26: ...with the equivalent results to fingertip testing What is the advantage Fingertips feel pain more readily because they are full of nerve endings receptors At other body sites since nerve endings are n...

Страница 27: ...s low You are unaware of hypoglycemia You are testing for hyperglycemia Your AST results do not match the way you feel Your routine glucose results are often fluctuating Performing a Blood Glucose Tes...

Страница 28: ...to obtain another drop of blood Be careful NOT to smear the blood sample The volume of blood sample must be at least 0 5 microliter L of volume actual size Step 4 Apply the Sample Gently apply the dro...

Страница 29: ...indow please contact your health care professional or the local customer service for assistance Step 5 Read Your Result The result of your blood glucose test will appear after the monitor counts down...

Страница 30: ...e measurement Wait 30 minutes after exercising or bathing before measurement Sit or lie down for at least 10 minutes before measurement Do not measure when feeling anxious or tense Take a 5 10 minute...

Страница 31: ...air tube and artery mark region in red toward the lower arm Step 4 Leave a little free space between the arm and the cuff you should be able to fit 2 fingers between them Clothing must not restrict th...

Страница 32: ...n of your heart Remain still and do not talk or move during the measurement Step 4 Measurement is in progress After the monitor is turned on the cuff will begin to inflate automatically Step 5 Press t...

Страница 33: ...turning on the monitor Taking a Single Measurement Step 2 The heart symbol will flash when a pulse is detected during the inflation Step 3 After the measurement the monitor displays the systolic press...

Страница 34: ...he right represents the remaining countdown between each measurement The monitor will take three 3 measurements consecutively with an interval of 20 seconds Step 1 Press The monitor will turn on and e...

Страница 35: ...ntil the remaining time is in 1 minute The number on the right represents the remaining seconds countdown from 59 between each measurement Step 2 The cuff will begin to inflate automatically After the...

Страница 36: ...the monitor will dis play End and press any key to turn off the monitor NOTE To discontinue the cycle mode measurement during the time intervals press and hold for 3 seconds to enter setting mode and...

Страница 37: ...ry To recall the memory start with the monitor off Reviewing Test Results Step 1 Press and release will appear on the display Step 2 Press Review all test results stored in the monitor Press to search...

Страница 38: ...until the flashing appears Release and then your blood glucose or blood pressure 7 day average result will appear on the display Step 2 Press Review your 14 and 30 day average Step 4 Exit the memory P...

Страница 39: ...atically Control solution results are NOT included in the day average If using the monitor for the first time displays when you recall the test results or review the average result This indicates that...

Страница 40: ...on the Bluetooth function on your mobile device 2 With the meter off Press to turn Bluetooth on PCL will appear on the display RF indicator on the meter BLUETOOTH INDICATOR STATUS Flashing Blue The Bl...

Страница 41: ...or above or Android System 4 3 or above has turned on Bluetooth before transmitting the data and the meter is within the receiving range The Bluetooth functionality is implemented in different ways by...

Страница 42: ...tch upload for current user with test results which have not been uploaded b setting the auto send On the meter will initiate 4G after measurement to send the current new data c in memory mode press t...

Страница 43: ...connecting to the server please try again If the problem still persists contact the place of purchase for help While the monitor is during data transmission it is unable to perform tests You could che...

Страница 44: ...mage the number displayed on the right represents the battery voltage value 38 if the number is below 37 it will be unable to initiate 4G transmission Press to turn off the monitor when you finish The...

Страница 45: ...est the symbol starts blinking Please recharge the battery immediately Recharging the Battery The power adapter can be used as the battery charger when you need to recharge Li ion battery To recharge...

Страница 46: ...f remove AC adapter power plug from the electrical outlet Step 2 Disconnect AC adapter plug from AC adapter jack of the monitor NOTE If the power indicator is blinking in red when connecting AC adapte...

Страница 47: ...or exterior wipe it with a cloth moistened with tap water or a mild cleaning agent then dry the device with a soft dry cloth Do NOT flush with water Do NOT use organic solvents to clean the monitor Do...

Страница 48: ...ediately close the vial cap tightly Touch the test strip with clean and dry hands Use each test strip immediately after removing it from the vial Write the opening date on the strip vial label when yo...

Страница 49: ...hs It is recommended that the control solution test should be done at room temperature 20 C to 25 C 68 F to 77 F Make sure your control solution monitor and test strips are at this specified temperatu...

Страница 50: ...E Appears when your result is below measurement limit which is less than 20 mg dL 1 1 mmol L Appears when your result is between 20 to 69 mg dL 1 1 to 3 8 mmol L It indicates the result is below refer...

Страница 51: ...mmediately Appears when your result is higher than the limit of measurement which is higher than 600 mg dL 33 3mmol L MESSAGE WHAT IT MEANS BLOOD PRESSURE Appears when your systolic pressure is below...

Страница 52: ...contact the local customer service for assistance E U Strip has been used Repeat the test with a new strip E F Test strip is removed while counting down or insufficient blood volume Review the instruc...

Страница 53: ...contact customer service for assistance PCL Err 39 Problem with reading SIM card Turn off the device and start over Follow the instructions and try again PCL Err 2 26 PCL Err 46 61 PCL Err 84 99 PCL...

Страница 54: ...d first and facing up Defective monitor or test strips Please contact customer service POSSIBLE CAUSE WHAT TO DO Insufficient blood sample Repeat the test using a new test strip with larger volume of...

Страница 55: ...peat the test again Expired or contaminated control solution Check the expiration date of the control solution Control solution that is too warm or too cold Control solution monitor and test strips sh...

Страница 56: ...an user s average 3 If the result is higher lower than user s average measurement POSSIBLE CAUSE WHAT TO DO Movement during measurement Repeat measurement Measurement taken just after exercise Rest at...

Страница 57: ...ood Pressure Clinical studies show that adult diabetes is often accompanied by elevated blood pressure People with diabetes can reduce their heart risk by managing their blood pressure along with diab...

Страница 58: ...imal 120 and 80 Normal 120 129 and or 80 84 High normal 130 139 and or 85 89 Grade 1 hypertension 140 159 and or 90 99 Grade 2 hypertension 160 179 and or 100 109 Grade 3 hypertension 180 and or 110 I...

Страница 59: ...Humidity limitation CE mark This device does not belong to household waste and must be returned to a collection point for recycling electric and electronic devices according to local laws If it contai...

Страница 60: ...PCL mode System operating condition 5 C to 40 C 41 F to 104 F 15 to 93 RH 700 hPa to 1060 hPa Monitor Storage Transportation condition 25 C to 70 C 13 F to 158 F 10 to 95 RH Power Supply Input DC 6V...

Страница 61: ...0 ANSI AAMI ISO 81060 2 NIBP requirements Blood pressure measurement performance Heart rate range 30 199 beat per minute Measurement unit mmHg Systolic Measurement Range 60 mmHg 250 mmHg Diastolic Mea...

Страница 62: ...d needs to be installed according to the EMC information provided Careful consideration of this information is essential when stacking or collocating equipment and when routing cables and accessories...

Страница 63: ...environment RF emissions CISPR 11 Group 1 The TD 3261G uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby elec...

Страница 64: ...are environment Surge IEC 61000 4 5 0 5kV 1kV line s to line s 0 5kV 1kV 2kV line s to earth 0 5kV 1kV line s to line s Not applicable Mains power quality should be that of a typical home healthcare e...

Страница 65: ...P 800MHz to 2 7 GHz Where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in metres m Interfe...

Страница 66: ...itter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 7 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3...

Страница 67: ...80 810 800 960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 Pulse modulation b 18 Hz 2 0 3 28 28 870 930 1 720 1 700 1 990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulatio...

Страница 68: ...nnected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not...

Страница 69: ...output power level in all frequency bands of the device D claration de FCC IC sur l exposition aux radiations RF Cet quipement doit tre install et utilis avec une distance minimale de 0 cm entre le r...

Страница 70: ......

Страница 71: ...TaiDoc Technology Corporation B1 7F No 127 Wugong 2nd Rd Wugu Dist 24888 New Taipei City Taiwan www taidoc com For self testing MedNet GmbH Borkstra e 10 48163 M nster Germany...

Отзывы: