52
8-3-8. SAMPLE AREA
Click SAMPLE AREA in the AUTO VIDEO OPTIMIZER menu to open the SAMPLE AREA
menu as shown below.
Item
Setting Description
Reference
(1) SAMPLE AREA
Allows you to set the sample area for the AVO
function.
[Setting range]
FULL SCREEN, CENTER,
ADJUST
[Default value]
FULL SCREEN
(2) AREA DISPLAY
Allows you to select whether to display SAMPLE
AREA selection marker on video output.
[Setting range]
ON, OFF
[Default value]
OFF
(3) START (H)
(4) END (H)
Allows you to set the horizontal size of the sample
area if ADJUST is selected under SAMPLE
AREA.
[Setting range]
0 to 704
[Default value]
START (H): 0, END (H): 704
* Odd values cannot be set. If an odd value is
entered, the value will be adjusted to the entered
value minus 1.
(5) START (V)
(6) END (V)
Allows you to set the vertical size of the sample
area if ADJUST is selected under SAMPLE
AREA.
[Setting range]
START: 0 to 227(NTSC)
0 to 267(PAL)
END:
1 to 228(NTSC)
1 to 268(PAL)
[Default value]
START(V) 0
END(V) 228(NTSC)/268(PAL)
(7) OK
Applies the settings to the IVS-200.
-
(8) MAIN MENU
Returns to the MAIN menu.
(9) AUTO VIDEO
OPTIMIZER
Returns to the AUTO VIDEO OPTIMIZER menu.
Содержание IVS-200
Страница 1: ...IVS 200 Video Stabilizer 1st Edition Rev 3 OPERATION MANUAL...
Страница 8: ......