5-5-3. SAMPLE AREA
Move the cursor over SAMPLE AREA on the AUTO VIDEO OPTIMIZER menu, and press the
menu control knob. The SAMPLE AREA menu as shown below opens.
Item
Setting Description
Reference
(1) Sample AREA
Allows you to set the sample area for the AVO function.
[Setting range]
FULL SCREEN, CENTER, ADJUST
[Default value]
FULL SCREEN
-
(2) START(H)
(3) END(H)
Allows you to set the horizontal size of the sample area
if ADJUST is selected under SAMPLE AREA.
[Setting range]
0 to 704
[Default value]
START(H) 0, END(H) 704
-
(4) START(V)
(5) END(V)
Allows you to set the vertical size of the sample area if
ADJUST is selected under SAMPLE AREA.
[Setting range]
START: 0 to 227(NTSC)/0 to 267(PAL)
END: 1 to 228(NTSC)/ 1 to 268(PAL)
[Default value]
START(V) 0,
END(V) 228(NTSC)/268(PAL)
-
(6) AUTO VIDEO
OPTIMIZER
Returns to AUTO VIDEO OPTIMIZER menu.
(7) MAIN MENU
Returns to the main menu.
(8) EXIT
Exits menus.
-
IMPORTANT
Sample Area determines the area in which data is sampled and the level adjustments
are applied to whole images.
5-5-4. RESPONSE
The Response menu allows you to set the filtering strength for calculating the mean
distances that are applied to histograms created using the sample data.
The larger the value, the more gradually filtering is performed, with a more stable image but
slower response.
The smaller the value, the less stable the image, but with a faster response.
5-5-5. GAMMA MODE
Allows you to enable or disable Gamma mode. On enables gamma level correction. Off
disables the correction.
(4)
(5)
(3)
(2)
(6)
(1)
(7)
SAMPLE AREA
→
SAMPLE
AREA
FULL
SCREEN
START
(
H
)
0
END
(
H
)
704
START
(
V
)
0
END
(
V
)
228
AUTO VIDEO OPTIMIZER
MAIN MENU
EXIT
<SAMPLE AREA>
(8)
Содержание IVS-200
Страница 1: ...IVS 200 Video Stabilizer 1st Edition Rev 3 OPERATION MANUAL...
Страница 8: ......