The device can be controlled using the DMX control console. To do so, select mode A001 and the DMX
address with a value between 1 and 512 using the UP, DOWN buttons and confirm with the ENTER button.
In the following table the device’s functions performed by the 7 DMX channels are shown. It is possible to
alternate their use freely among several channels simultaneously.
It is possible to connect several devices controlled via the DMX-512, interconnecting them using XLR cables
with the following configuration:
- Connect the device to the mains supply and switch it on.
- It is possible to connect several devices in cascade to be managed collectively or separately. Connect an
XLR cable between DMX IN input of the device and the DMX OUT output of the DMX control console if it
is the first element in the chain, or the DMX OUT of the previous element in the chain of your show lighting
assembly.
- The total interconnection wiring of devices in a line must not exceed 100 meters. To avoid interference in
the line, it is advisable to place a line terminator consisting in a resistance of 120 Ω between the terminals
2 and 3 of the XLR DMX OUT connector of the last element. See diagram below:
DMX 512 CONTROL CONSOLE FUNCTIONS
DMX CH.
DMX VALUE
FUNCTION
1
0-255
DIMMER
2
0-255
RED DIMMER
3
0-255
GREEN DIMMER
4
0-255
BLUE DIMMER
5
0-255
STROBE
6
1-255
SPEED
7
1-255
MACRO