EN
- 5 -
- Slightly adjust the volume controls with a screwdriver until the desired volume is reached and check
the coverage in the entire area. The shape of these controls and their position on the amplifi er prevents
accidental misadjustments that may cause injury or discomfort to users.
- IMPORTANT :
- Switch off the amplifi er whenever you are not going to use it.
- Periodically check the correct operation of the equipment.
Condenser
microphone
Induction
loop
TECHNICAL SPECIFICATIONS
AUDIFON-V
FEATURES
Tele-coil hearing aid loop amplifi er.
Complete kit for installation on counter and or teller window.
FUNCTIONS
1.2 m
2
counter loop
Extendable up to 20 m2 (using a 4.5 x 4.5 m loop in 4 loops)
LED operation indicators.
Countertop or under-counter installation.
POWER
5 W RMS, THD 2.5%
FREQUENCY
RESPONSE
35 - 20k Hz, -10 dBA
DISTORSION
THD+N <0’2%, 1 kHz, 1W
PROTECTIONS
Overheating and overloading
CONTROLES
On/off
Microphone and AUX volume.
Output volume.
INPUTS
1 clip-on microphone, 3.5 mm TS jack, 1.5 mV, Phantom 5 V 1 mA
1 AUX, 3.5 mm TRS jack, 250 mV
OUTPUTS
1 Loop, Euroblock
LOOP IMPEDANCE
0.5 - 3 Ohm
CURRENT
2 A
POWER SUPPLY
12 V DC, 1 A with adapter included
Power consumption: 10 W
Standby power consumption: 0.5 W
DIMENSIONS
Amplifi er: 155 x 35 x 35 x 75 mm depth
Clip-on microphone cable: 1.40 m
70 x 70 cm loop cable (1.2 m2 coverage) with 1.8 m extension cable
ACCESSORIES
Unidirectional clip-on microphone
Loop cable
Adhesive T