SOLENOID VALVES SV1 and SV2
ELECTRICAL CONNECTIONS
The valve features a compensation pressure point connected to the combustion chamber
through a silicone pipe.
Valve thus knows the pressure on nozzles and can supply the correct quantity of gas even
in case of overpressure or vacuum inside the chamber.
Upon ignition, for example, when fan is activated a vacuum develops inside the
combustion chamber, and valve (thanks to this pressure point) decreases nozzle pressure
so as to balance any exceeding gas supply due to vacuum.
At the valve outlet there are two gas regulating nozzles inside the mixer, to be replaced in
case of gas conversion (see following paragraph).
The following table indicates the diameters of said nozzles according to the different power
rates and types of fuel:
Nozzle diameter
[mm]
Thermal output
Natural
gas
LPG
12 kW
3.05 2.5
24 kW
3.7 3.0
28 kW
4.0 3.3
Mixer exploded view for nozzle position:
Resistivity values
Ev1
≈
1600
Ev2
≈
6.70 k