Specifications
Electrical
Each icemaker and dispenser require a separate circuit with with electrical disconnect within 10 ft (6m).
Equipment ground required. Standard electrical – 115V, 60Hz, 1 phase. Maximum dispenser fuse – 15 amps,
Maximum icemaker fuse – 20 amps each.
Model
Icemaker
Dispenser
number
amperage
amperage
VU155M series
11.0 amps ea
2.4 amps
(no integral beverage cooling)
VU155B series
11.0 amps ea
4.4 amps
(integral beverage cooling)
Plumbing
Dispenser
3/4" PVC pipe nipple for bin drain
3/4" PVC pipe nipple for drain pan drain
1" ID hose for beverage bath drain
Beverage connections
1/4" ID syrup beverage hose
3/8" ID carbonated water beverage hose
3/8" ID plain water beverage hose
Note:
Drains should be hard piped and insulated. Maintain at least 1/4" per foot (6mm per 304mm run)
slope on drain line run.
Water disconnect within 10 feet (3m) of dispenser is suggested for automatic load units.
Follett recommends use of a Follett water filter (part# 00130229)on icemakers connected
to automatic fill dispensers.
Icemaker
Refer to detailed specifications in icemaker installation manual packed with icemaker
4