Plumbing
Dispenser
- 3/4" PVC slip joint for hopper drain
3/4" PVC pipe nipple for beverage drain pan
3/4" PVC pipe nipple for bath overflow
Note: Drains should be hard piped and insulated. Maintain at least 1/4" per foot (6mm per
30.4cm run) slope on drain line run.
Icemaker
- Refer to Icemaker Installation Manual packed with icemaker for installation instructions
1/4" FPT water in
1/2" MPT drain
3/8" FPT condenser inlet (water cooled condenser only)
1/2" FPT condenser drain (water cooled condenser only)
Water disconnect within 10 feet (3 meters) of dispenser is suggested for automatic load units.
Beverage connections
• Dispenser is provided with 1/4" syrup, 3/8" carbonated water and 3/8" plain water pigtails
Clearance and access information
• 51" (1296mm) above counter
• 12" (305mm) on side opposite tower, below counter
• Counter front or rear panel must be removable for service access to both sides of dispenser and
icemaker(s), (if any)
• Below counter access to drain clean-out required on utility side of dispenser
• See Icemaker Installation Manual packed with icemaker(s) for clearance requirements for automatic load
dispensers
3
17"
(432mm)
6"
min
12"
min
18.9"
(481mm)
PVC
joint
drain
slip
3/4"
beverage line
air break*
electrical
connections
31.25"
(794mm)
21.75"
(553mm)
28"
(712mm)
counter top
49.75"
(1264mm)
(8 valve unit)
(10 valve unit)
37.25"
(947mm)
Manual load units
Automatic load units with 1 icemaker
Automatic load units with 2 icemakers
27.375"
(696mm)
ice transport
tube entrance
6"
(153mm)
25.8"
(656mm)
bin
signal
power
8.75"
(223mm)
3/4 PVC
slip joint
drain
18.5"
(470mm)
air
beverage
waterbath
overflow
break*
beverage
drain pan
drain
*DO NOT
CONNECT TO
DRAIN SYSTEM
3.5"
(89mm)
Side view - right hand dispenser
(side opposite dispense tower)
Front view — units with up to 10 beverage valves