4
Specifi cations
Electrical
1.
Models with Satellite-fi ll icemakers (25CR400A/W, 50CR400A/W, 25HR400A/W, 50HR400A/W)
Icemaker
Max. fuse
Dispenser
Max. fuse
Basic electrical: 115V/60Hz/1 phase
11.0 amps
20 amps
4.0 amps
20 amps
2.
Freestanding models and models with integral icemakers (25FB400A/W, 50FB400A/W,
25CT400A/W, 50CT400A/W, 25HT400A/W, 50HT400A/W)
Total system Max. fuse
Basic electrical: 115V/60Hz/1 phase
14.0 amps
20 amps
3.
Dispensers and Satellite-fi ll icemakers are supplied with 7-foot power cord with NEMA 5-20 hospital grade
plug. Connect to 20 amp circuit fuse or breaker.
Note:
It is preferred that circuit be protected by a GFCI.
Ambient
Air temp
+100 F/+38 C max. +50 F/+10 C min. (best performance below +80 F/+27 C)
Water temp
+90 F/+32 C max. +40 F/+4 C min. (best performance below +70 F/+21 C)
Water pressure
70 P.S.I. max.
10 P.S.I. min.
Plumbing
25/50 CR with
25/50 HR with
25/50 CT with
25/50 HT with
25/50 FB
Satellite-fi ll
Satellite-fi ll
integral
integral
icemaker
icemaker icemaker icemaker icemaker
in
base
Dispenser drain
3/4" FPT
3/4" ID tubing
3/4" FPT
3/4" ID tubing
3/4" FPT
Icemaker drain
3/4" MPT
3/4 MPT
–
–
3/4" MPT
Dispenser water inlet
3/8" FPT
3/8" FPT
3/8" FPT
3/8" FPT
3/8" FPT
Satellite-fi ll IM water inlet
3/8" OD push-in
3/8" OD push-in
–
–
–
Cond. inlet – w/c only
3/8" FPT
3/8" FPT
3/8" FPT
3/8" FPT
3/8" FPT
Cond. drain – w/c only
3/8" FPT
3/8" FPT
3/8" FPT
3/8" FPT
3/8" FPT
Note:
Water shut-off recommended within 10 feet (3m) of dispenser. Drain to be hard piped and insulated, and maintain
slope of at least 1/4" per foot (6mm per 30.4cm run) of slope. All plumbing connections must be made in accordance with
local building codes.
Ventilation clearances
Countertop and wall mount models with Satellite-fi ll icemaker (25CR400A/W, 50CR400A/W, 25HR400A/W,
50HR400A/W) — none. 12" (305mm) at top advised for service.
Countertop and wall mount models with integral icemaker (25CT400A/W, 50CT400A/W, 25HT400A/W,
50HT400A/W) — 6" (153mm) at top. 6" (153mm) each side advised for service.
Freestanding models (25FB400A/W, 50FB400A/W) — 4" (102mm) at rear. 12" (305mm) at top advised
for service.