5
VISION • SATELLITE-FILL
remote condensing
HCC1000R/N
HCC1400R/N
➎
➍
5/8"
∅
(15,8mm)
3/8"
∅
(9,5mm)
NEMA
5-15
➋
➊
➋
1/4"
1'
➌
Prepare the installation site.
2
Site preparation
2.1
Provide drainage, water supply and electrical power to within 6 feet (2m) of
icemaker in accordance with local and national codes. Outdoor installation of
low side is not recommended and will void warranty.
Electrical
➊
• HCC1000(R/N)VS 120/60/1-6 amps
• HCC1400(R/N)VS 120/60/1-6 amps
Potable water supply
➋
• 10-70 psi (69-483kpa)
• 45-90 F (7-32 C)
• Follett recommends the use of an in-line water filtration system (item# 00130286)
Drain
➌
• The drain line from the icemaker must have at least 1/4" per foot pitch (6,4mm/0,3m)
Refrigeration lines
➍
• 5/8" (15,8mm) diameter suction (insulated)
➍
• 3/8" (9,5mm) liquid
➎
Installation site requirements
2.1