Prepare the dispenser.
3
Dispenser preparation
Ground
24"
(610 mm)
➎
➏
➍
➌
➌
➋
➊
➏
• Mount the electrical box to the side of the Vision dispenser
➊
to establish a ground
connection.
Note:
If a 4 x 4 box is mounted to a non-grounded surface, connect ground wire at an
appropriate ground.
• Connect the bin signal plug on the electrical box to the bin signal cord on the bin
➋
• Insert 24" (609,6mm) of the long bin signal cable
➌
into the hole in the back of the louvered
docking station
➍
and secure in place with strain relief provided.
• After sliding the icemaker module into the louvered docking station, disconnect the shuttle
plug
➎
from the icemaker control box.
• Complete normal installation procedure for the icemaker using the installation manual that
shipped with the icemaker.
• Connect the bin signal plug
➏
into the icemaker control box.