12
Horizon Elite 710/1010/1410
HARMONY • RIDE Technology
5.2
Air-cooled ice machines only
5.3
Water-cooled ice machines only
3/4" barb x 3/4" FPT
1" Stand pipe/Drain
2 ft. x 1" OD
silicone tubing
Minimum 8"
radius
➍
3/4" MPT x 1" slip
➎
➌
➋
➊
➏
➏
➌
➋
➐
➑
3/4" barb x 3/4" FPT
1" Stand pipe/Drain
2 ft. x 1" OD
silicone tubing
Minimum 8"
radius
3/4" MPT x 1" slip
➍
➎
➊
§
Rough-in ice machine potable water supply
➊
. 3/8"
push-in connection will be made at included shut-off
valve then at back of docking station into solenoid.
§
Remove access panel if necessary
➋
.
§
Connect the silicone tubing to the ice machine 3/4"
drain barb
➌
.
§
Assemble the 3/4" barb x 3/4" FPT to the 3/4" MPT
x 1" slip. Connect the other end of the silicone
tubing to the 3/4" barb
➍
.
§
Connect the 1" slip fitting to the 1" stand pipe/drain
➎
.
Note: Minimum 8" radius on silicone drain line.
Drain line from the ice machine must have
at least 1/4" per foot pitch (6,4mm/0,3m).
§
Apply Petrol-gel to barbed drain fitting
➏
§
Replace access panel.
§
Rough-in ice machine potable water supply
➊
.
3/8" push-in connection will be made at included
shut-off valve then at back of docking station into
solenoid.
§
Remove access panel if necessary
➋
.
§
Connect the silicone tubing to the ice machine
3/4" drain barb
➌
.
§
Assemble the 3/4" barb x 3/4" FPT to the 3/4"
MPT x 1" slip. Connect the other end of the
silicone tubing to the 3/4" barb
➍
.
§
Connect the 1" slip fitting to the 1" stand pipe/
drain
➎
.
Note: Minimum 8" radius on silicone drain
line. Drain line from the ice machine
must have at least 1/4" per foot pitch
(6,4mm/0,3m).
§
Connect cooling water supply
➏
and return
➐
§
Apply Petrol-gel to barbed drain fitting
➑
§
Replace access panel.