HARMONY • RIDE Technology
Horizon Elite 710/1010/1410
19
8.
Dispenser Agitation Adjustment
8.1
Agitation adjustments
- Cornelius
5
4.5
4
3.5
3
2.5
2
1.5
1
.5
3
HRS
2.5
HRS
2
HRS
1.5
HRS
1
HR
30
MIN
MOTOR ON TIME:
SET TO 1 SECOND
MOTOR OFF TIME:
SET TO 1 HOUR
10
MIN
ON
TIME
OFF
TIME
E-BOARD AGITATOR TIMER
Cornelius models ED, DB, DF, IDC
and Flavor Fusion
§
Adjust the agitation tier located on the Cornelius PC board to 1 second on, 1 hour off.
Note: See Cornelius manual or call Cornelius Technical Service at 1-800-238-3600 for more information.
8.2
Agitation adjustments – Lancer 4500 Series
PRESS IN ON
THIS SIDE TO
TURN SWITCH
ON.
PRESS IN ON
THIS SIDE TO
TURN SWITCH
OFF.
ROCKER
SWITCHES
(VIEW LOOKING
DOWN)
SWITCH
NUMBER
5
6
7
8
SWITCH
NUMBER
1 SECOND
3
4
OFF
OFF
150 MINS
ON
ON
ON
ON
AGITATION TIME
AGITATION FREQUENCY
OFF
OFF
OFF
OFF
OFF
OFF
OFF
SWITCH
OFF
SIDE VIEW
SWITCH
ON
SIDE VIEW
OFF
Lancer 4500 series only
Adjust the agitation time to 1 second, and the agitation frequency to 150 minutes. See Lancer manual or call
Lancer Customer Service at 1-888-846-6729 for more information