8
remote condensing
DROP-IN • RIDE Technology
No Lip
➋
Access panel/
door on counter
3.25" (83 mm) min.
➊
➌
24" min.
(609 mm
22.25" min.
(656 mm)
CROSSBRACE
Top View
DOCKING STATION
• Prior to installing the docking assembly, ensure that the drain fitting is oriented (right or left)
correctly for your installation. An optional straight drain fitting is also supplied. You may need to
remove the back panel of the docking assembly in order to re-orient or change the drain fitting.
Replace back panel prior to mounting the docking assembly.
• Position and screw docking assembly to the bottom of counter inside of access panel/door min.
of 3.25" (83 mm) from the front edge of the cross brace
➊
• The mounting surface for the docking assembly must be solid.
Do not mount directly onto runners or channels.
• There must be no lip or edge that would hinder the ice machine from sliding in or out of the
docking station
➋
• Ice machine must be installed facing forward as shown for service accessibility
➌
Undercounter installation requirements
4.2