Plumbing
§
3/8" OD push-in water inlet
§
3/4" MPT drain
§
3/8" FPT condenser inlet (water-cooled condenser only – 1.25 gpm minimum available flow)
§
3/8" FPT condenser drain (water-cooled condenser only)
Notes:
§
Slope to drain of 1/4" per foot (6 mm per 30.4 cm run) with a 1/2" min. is recommended.
§
Water shut-off recommended within 10 feet (3 m), drain to be hard piped and insulated.
§
Separate drains for ice machine and condenser. To prevent back flow, do NOT connect drains.
§
Follett recommends a Follett water filter system be installed in the ice machine inlet water line (standard capacity
#00130299, high capacity #00978957, carbonless high capacity #01050442).
Ambient
Air temperature
100 F/38 C max.
50 F/10 C min. (best performance below 80 F/27 C)
Water temperature
90 F/32 C max.
40˚F/4˚C min. (best performance below 70 F/21 C)
Water pressure
70 P.S.I max. (482 kPA)
10 P.S.I. min. (89 kPA)