6
Dimensions and clearances
Entire front of ice machine must be clear of obstructions/connections to allow removal.
1" (26mm) clearance above ice machine for service.
1" (26mm) minimum clearance on sides.
The intake and exhaust air grilles must provide at least 150 sq in (968 sq cm) of open area.
Air-cooled model ice machines – 18" (458mm) minimum clearance between discharge and air intake-grilles.
Front View
Side View
Back View
Air intake
PSIG
THE USA
MADE IN
OZ
PHASE
SINGLE
LOW SIDE
CHARGE
PART NO
R
R
HZ
Easton Pennsylvania
208264
AMPS
AMPS
VOLTS
SERIAL NO
CORPORATION
MODEL
Service No.
Product
Module No.
REFRIGERANT
FULL LOAD AMPS
Stock Module Identification Plate
DESIGN PRESSURE HIGH SIDE
MAX. BRANCH CIRCUIT FUSE SIZE
MIN. BRANCH CIRCUIT AMPACITY
MOTOR COMPRESSOR THERMALLY PROTECTED
C
NSF
UL
UL
Air exhaust
21.05" (535mm)
23.50"
(597mm)
21.28" (541mm)
Air exhaust
both sides
Ice transport hose connection
6.95"
(177mm)
3/4" MPT drain
3/8" OD push-in water inlet
23.77" (604mm)
15.56"
(396mm)
2.53"
(65mm)
2.43" (62mm)
1/4" FPT condensor drain
(water-cooled only)
1/4" FPT condensor inlet
(water-cooled only)
29.63" (753mm)
Cord only
CAUTION
• Keep ventilation openings in the appliance enclosure or built-in structure, clear of obstruction