If you want to make an outdoor installation, you must purchase the Outdoor air intake kit.
- For air inlet kit Ø80mm - PA1090G035 (For E601 and E609 models only).
- For air inlet kit Ø100mm - PA1090G057.
To make this connection, you must use a flexible hose from the air intake kit of the unit to the outside of the
house.
10.2. Hot air outlet (B)
This control mechanism operates either fully open or fully closed. If the mechanism is fully open, it allows the
projection of hot air into the room, heating it, if it is fully closed, it prevents the projection of hot air into the room,
in this closed mode, if there are secondary air vents installed, it will allow other rooms in the house to be heated,
the mechanism in closed mode will allow heat to be channelled more efficiently through the secondary air vents to
other rooms, see Figure 22 and Figure 23.
Warning:
If you have secondary hot air vents installed, at least one (usually the one in the largest room) must be
permanently open. If, by accident, all the grilles and the cover inside the stove are closed, then the heat will short-
circuit and, within some time, burn out the fan. The fan is sure to short-circuit when there is a significant and
sudden increase in noise.
Figure 22 - Hot air outlets
a)
b)
Figure 23 - a) Fan warm air control mechanism Open, b) Fan warm air control mechanism Closed
Hot Air Outlets